35
4.
Release the override switch.
5.
Press and release the override switch.
The LED will now report the last system shutdown by flashing for one minute in the below grouped
patterns; the LED will stop flashing when the ignition is turned on.
Remote Sensor Bypass
Remote Sensor Bypass allows the operator to select which inputs and sensors are active during a
particular arming cycle. For a full description of Remote Sensor Bypass operation for testing
purposes refer to the owner's manual.
LED FLASHES
SHUTDOWN MODE
One
System timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Remote Shutdown (or optional push-button)
Six
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
Seven
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Eight
Wait-to-start timed out