beautypg.com

2 system exclusive protocol parameter, 3 data management parameter – Casio CTK6000 User Manual

Page 50

background image

24.2

System Exclusive Protocol Parameter

These parameters are related to the System Exclusive message protocol.

Parameter

ID

R/W

Block

Size

Array

Min-Def-Max

Description

Oneway Min Interval

000E

R

00000000

14

01

0000-0014-3FFF

Minimum time interval time value (msec)
between packets during One-way Bulk Dump
receive by Instrument

Oneway Max Interval

000F

R/W

14

01

0000-0800-3FFF

Maximum allowable message wait time
(msec) during One-way Bulk Dump receive
by Instrument

Oneway Current Interval

0010

R/W

14

01

0000-0014-3FFF

Current time interval value between
packets during One-way Bulk Dump send by
Instrument

Oneway Max Data Length

0011

R

14

01

0000-0080-3FFF

Maximum memory size value (bytes) of
transfer data included in one packet
during One-way Bulk Dump send/receive by
Instrument

Oneway Curent Data Length

0012

R/W

14

01

0000-0080-3FFF

Current memory size value (bytes) of
transfer data included in one packet
during One-way Bulk Dump send by
Instrument

Handshake Max Interval

0013

R/W

14

01

0000-0800-3FFF

Maximum allowable message wait time
(msec) during Handshake Bulk Dump receive
by Instrument

Handshake Max Data Length

0014

R

14

01

0000-0080-3FFF

Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump send/receive
by Instrument

Handshake Currnet Data Length

0015

R/W

14

01

0000-0080-3FFF

Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump send by
Instrument

Handshake Retry Number

0016

R/W

7

01

00-03-7F

Number of retries after error generation
during Handshake Bulk Dump send

24.3

Data Management Parameter

These are information acquisition and operation command parameters for this Instrument’s Data Man-
ager PC application.

50