24.2
System Exclusive Protocol Parameter
These parameters are related to the System Exclusive message protocol.
Parameter
ID
R/W
Block
Size
Array
Min-Def-Max
Description
Oneway Min Interval
000E
R
00000000
14
01
0000-0014-3FFF
Minimum time interval time value (msec)
between packets during One-way Bulk Dump
receive by Instrument
Oneway Max Interval
000F
R/W
14
01
0000-0800-3FFF
Maximum allowable message wait time
(msec) during One-way Bulk Dump receive
by Instrument
Oneway Current Interval
0010
R/W
14
01
0000-0014-3FFF
Current time interval value between
packets during One-way Bulk Dump send by
Instrument
Oneway Max Data Length
0011
R
14
01
0000-0080-3FFF
Maximum memory size value (bytes) of
transfer data included in one packet
during One-way Bulk Dump send/receive by
Instrument
Oneway Curent Data Length
0012
R/W
14
01
0000-0080-3FFF
Current memory size value (bytes) of
transfer data included in one packet
during One-way Bulk Dump send by
Instrument
Handshake Max Interval
0013
R/W
14
01
0000-0800-3FFF
Maximum allowable message wait time
(msec) during Handshake Bulk Dump receive
by Instrument
Handshake Max Data Length
0014
R
14
01
0000-0080-3FFF
Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump send/receive
by Instrument
Handshake Currnet Data Length
0015
R/W
14
01
0000-0080-3FFF
Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump send by
Instrument
Handshake Retry Number
0016
R/W
7
01
00-03-7F
Number of retries after error generation
during Handshake Bulk Dump send
24.3
Data Management Parameter
These are information acquisition and operation command parameters for this Instrument’s Data Man-
ager PC application.