OPERATION
1. Press and hold the Infinity Key for two seconds to bring up
the Home Page.
2. Use the Up and Down Arrow Keys to adjust the set point
temperature if necessary. The lower display of the Home
Page shows the set point temperature. The set point
temperature needs to be slightly higher than the melting
point and significantly lower than the flash point or boiling
point of the liquid being pumped.
WARNING !
Depending on the set point temperature at
startup, the controller may deliver power to
the heat cartridges and cause them to heat as
soon as the controller is turned on.
WARNING !
Setting the set point temperature higher than
necessary will not make the pump heat any
faster and will shorten the life of the heat
cartridges.
3. To make sure that the liquid within the pump is melted and
to avoid damage to the pump, do not start the pump until
the set point temperature has been reached. Depending
on your setup, there may be a ready light to indicate when
the set point has been reached. On the Home Page, the
upper display shows the process temperature, and the
lower display shows the set point temperature.
!
!
kEY LAYOUT AND FUNCTIONS
Upper Display
In the Home Page, displays the
process value, otherwise displays
the value of the parameter in the
lower display.
Temperature Units
Indicates whether the
temperature is displayed in
Fahrenheit or Celsius.
Zone Display
Indicates the
controller zone.
Percentage Units
Lights when the controller
is displaying values as a
percentage.
EZ key
Not Used
Output Activity
Number LEDs indicate activity
of outputs. A flashing light
indicates output activity.
#2 indicates when power
applied to heaters.
Lower Display
Indicates the set point
or output power value
during operation, or the
parameter whose value
appears in the upper
display.
Up and Down Arrow keys
In the Home Page, adjusts the
set point in the lower display.
In other pages, changes the
upper display to a higher or
lower value, or changes the
parameter selection.
Infinity key
Press to back up one level, or press and hold for two
seconds to return to the Home Page. From the Home
Page, you can clear alarms and errors if clearable.
Advance key
Advances through parameter prompts.
NOTE:
This controller has been pre-
programmed by Viking Pump
to lockout many functions
to simplify installation and
operation for customer specified
electric heat applications.
If advanced functionality is
required, the user should
source their own controller from
a qualified heat control vendor.