beautypg.com

Shield – Tweco XT-301 Torch Data for Distributor use w- Auto-Cut 30O2 AE User Manual

Page 38

background image

TORCH DATA for AutoCut O

2

8-38

Manual 0-4831 Rev. AE

(ga)

(in)

inch

psi

Ball

psi

Ball

psi

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

20

120

100

NA

120

160

0.350

85

0.350

0.2

0.175

1/2

0.500

20

120

100

NA

120

168

0.350

75

0.350

0.4

0.193

5/8

0.625

20

120

100

NA

90

163

0.350

65

0.375

0.5

0.197

3/4

0.750

20

120

100

NA

90

168

0.350

55

0.375

0.6

0.195

7/8

0.875

20

120

100

NA

90

170

0.350

45

0.375

0.7

0.210

1

1.000

20

120

100

NA

120

173

0.350

35

0.500

0.9

0.226

1 1/4

1.250

20

120

100

NA

120

180

0.400

30

0.500

1.0

0.203

1 1/2

1.500

20

120

100

NA

120

180

0.400

25

0.220

2

2.000

20

120

100

NA

120

186

0.400

17

0.237

bar

Ball

bar

Ball

bar

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

120

6.9

NA

8.3

161

8.9

2120

8.9

0.2

4.5

1.4

120

6.9

NA

8.3

166

8.9

1960

8.9

0.4

4.8

1.4

120

6.9

NA

6.2

164

8.9

1720

9.4

0.5

5.0

1.4

120

6.9

NA

6.2

169

8.9

1320

9.5

0.6

5.1

1.4

120

6.9

NA

8.3

173

8.9

920

12.3

0.9

5.7

1.4

120

6.9

NA

8.3

180

10.2

760

12.2

1.0

5.2

1.4

120

6.9

NA

8.3

180

10.2

640

5.6

1.4

120

6.9

NA

8.3

183

10.2

540

5.8

1.4

120

6.9

NA

8.3

186

10.2

450

6.0

300A
Stainless Steel
H35 Plasma / N

2

Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later

44

Edge Start

50

Edge Start

25

32

38

Edge Start

10

12

15

20

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield

(N2)

(mm)

Edge Start

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield

(N2)

Edge Start

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates /

Pressures

Arc

Voltage

35-1043

35-1091

35-1022

35-1015

< 1" / 25mm 35-1035,

1" / 25mm + 35-1036

35-1284

35-1061

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

Cartridge

Electrode

Shield

Shield Gas
Distributor

Tip

Plasma Gas

Distributor

Shield Retainer

Art # A-07917_AC