200a stainless steel n, Plasma / h, O shield – Tweco XT-301 Torch Data for Distributor use w- Auto-Cut 30O2 AE User Manual
Page 27
![background image](/manuals/595507/27/background.png)
Manual 0-4831 Rev. AE
8-27
TORCH DATA for AutoCut O
2
(ga)
(in)
inch
(PSI)
(Ball) (PSI)
(Ball
)
(PSI)
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
3/8
0.375
20
80
90
5
55
155
0.160
95
0.300
0.0
0.110
1/2
0.500
20
80
90
5
55
156
0.160
85
0.300
0.4
0.115
5/8
0.625
20
80
90
5
55
158
0.180
65
0.300
0.5
0.122
3/4
0.750
20
80
90
5
55
163
0.200
50
0.300
0.7
0.133
7/8
0.875
20
80
90
5
55
177
0.250
40
0.400
0.9
0.149
1
1.000
20
80
90
5
55
183
0.300
35
0.450
1.0
0.148
1 1/4
1.250
20
80
90
5
55
185
0.300
20
0.176
1 1/2
1.500
20
80
90
5
55
200
0.350
10
0.211
1 3/4
1.750
20
80
90
5
55
207
0.350
8
0.216
(Bar)
(Ball) (Bar)
(Ball
)
(Bar)
Volts
(mm)
±0.1
(mm/min)
(mm)
(sec)
(mm)
1.4
80
6.3
5
3.8
155
4.1
2400
7.6
0.0
2.8
1.4
80
6.3
5
3.8
156
4.1
2000
7.6
0.4
2.9
1.4
80
6.3
5
3.8
157
4.4
1550
7.6
0.5
3.1
1.4
80
6.3
5
3.8
165
5.1
1100
7.6
0.7
3.4
1.4
80
6.3
5
3.8
183
7.6
900
11.4
0.9
3.7
1.4
80
6.3
5
3.8
185
7.6
500
4.5
1.4
80
6.3
5
3.8
200
8.9
250
5.4
1.4
80
6.3
5
3.8
206
8.9
200
5.5
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.
Edge Start
Edge Start
25
32
44
Edge Start
Edge Start
15
Material
Thickness
Pre Flow
Pressure
(N
2
)
200A
Stainless Steel
N
2
Plasma / H
2
O Shield
Edge Start
35-1020
35-1016
35-1039
35-1273
35-1064
Plasma Gas
Distributor
Electrode
Cartridge
Shield Cup
Shield Cap
Shield Gas
Distributor
Tip
35-1048
35-1089
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Cut Flow Rates /
Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Shield
(H
2
O)*
Initial
Piercing
Height
38
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures
10
12
(mm)
Edge Start
20
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.
Pierce
Delay
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
Arc
Voltage
Torch
Working
Height
Travel
Speed
Electrode
Shield Cap
Tip
Shield Gas
Distributor
Plasma Gas
Distributor
Cartridge
Shield Cup
This Art Is For Reference ONLY
Art # A-07958_AB