Manual 0-5145
FAULT
CAUSE
REMEDY
7 Dirty weld pool
A Electrode contaminated
by contact with work
piece or filler rod mate-
rial.
A Clean the electrode by grinding off the con-
taminates.
B Work piece surface has
foreign material on it.
B Clean surface.
C Gas contaminated with
air.
C Check gas lines for cuts and loose fitting or
change gas cylinder.
8 Poor weld finish
Inadequate shielding
gas.
Increase gas flow or check gas line for gas
flow problems.
9 Arc start is not smooth.
A Tungsten electrode is
too large for the weld-
ing current.
A Select the right size electrode. Refer to Table
4-7 Current Ranges for Various Tungsten
Electrode Size.
B The wrong electrode
is being used for the
welding job.
B Select the right electrode type. Refer to Table
4-9 Tungsten Electrode Types.
C Gas flow rate is too
high.
C Select the right rate for the welding job. Refer
to Table 4-10.
D Incorrect shielding gas
is being used.
D Select the right shielding gas.
E Poor work clamp con-
nection to work piece.
E Improve connection to work piece.
F Tungsten not properly
sharpened.
F Grind tungsten to proper shape.
10 Arc flutters during TIG
welding.
Tungsten electrode is
too large for the weld-
ing current.
Select the right size electrode. Refer to Table
4-7 Current Ranges for Various Electrode
Size.
11 Tungsten blackens due to
lack of shielding gas or
wrong shield gas.
A Gas valve on the TIG
Torch has not be turned
on.
A Turn on TIG Torch gas valve before you
commence welding.
B Gas cylinder valve off
or TIG Torch hose not
connected to regulator
B Turn on gas cylinder valve or connect TIG
Torch hose to regulator.
C Incorrect shielding gas
is being used.
C Select the right shielding gas.
Table 4-10: TIG (GTAW) Welding Problems