APPENDIX

APPENDIX I: INPUT WIRING REQUIREMENTS

NOTES

The table above is based on the following output current and voltage: 125VDC @ 40A

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Flexible cable must have an outside diameter of 0.69 inches (17.5 mm) or greater.

Input

Power Input

Current Input

Suggested Sizes (See Notes)

Voltage Freq.

1-Ph

3-Ph

1-Ph

3-Ph

Fuse (Amps)

Wire (mm2)

(Volts)

(Hz)

(kVA)

(kVA) (Amps) (Amps) 1-Ph

3-Ph

1-Ph

3-Ph

220

50/60

8.2

7.2

37.2

19

45

25

10

6

380

50/60

8.6

13

20

2.5

415

50/60

8.6

12

20

2.5

Line Voltages with Suggested Circuit Protection and Wire Sizes