beautypg.com

Tweco 81 with SL100SV User Manual

Page 85

background image

Manual 0-4641

5-21

SERVICE

5

D. Torch will not pilot when torch switch is activated; AC

and GAS

indicators ON; Temp and DC

indicators OFF

1. Gas pressure too high or too low

a. Adjust gas pressure per pressure setting label on power supply.

2. Torch tip, start cartridge, or electrode missing.

a. Turn off power supply. Remove shield cup, install missing parts.

3. Start cartridge is stuck

a. Turn off power supply. Remove shield cup, tip, and start cartridge. Check lower end fitting on start cartridge

for free movement. Replace cartridge if lower end fitting does not move freely.

Art # A-07168

Spring-Loaded Cylinder
at Full Compression

Spring-Loaded Cylinder
at Full Extension

1/8” (3 mm)

4. Worn or faulty torch parts

a. Inspect torch consumable parts. Replace if necessary.

E. Gas flows; AC indicator

and GAS

indicators ON; TEMP indicator off; ON; DC

indicator

off or blinks on/off once.

1. Faulty IGBT or Output Diode Module Assembly(s)

a. Check per Subsection 5.08-C; repair as needed.

2. Faulty Main PCB

a. Test; repair as needed.