beautypg.com

04 gas connections, Gas connections -2, Cutmaster 25mm – Tweco 25mm Cutmaster User Manual

Page 26

background image

CUTMASTER 25MM

INSTALLATION

Manual 0-5080

3-2

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back

the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Set Jumper wires on the contactor. See illus-

tration.

• Green / Yellow wire to Ground.

• Remaining wires to L1, L2 and L3 input. It

does not matter what order these wires are

attached. See the previous illustrations.

7. With a little slack in the wires, tighten the through

- hole protector to secure the power cable.

8. Reinstall the Power Supply cover per instructions

found in section 5.

9. Connect the opposite end of individual wires to

a customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.

3.04 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air or high

pressure cylinders. Refer to the following two subsec-

tions if an optional air line filter is to be installed.

1. Connect the air line to the inlet port. The illustra-

tion shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do not use Teflon tape as a

thread sealer, as small particles of the tape

may break off and block the small air pas-

sages in the torch.

Art # A-07943

Hose Clamp

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

1/4 NPT or ISO-R

to 1/4” (6mm) Fitting

Air Connection to Inlet Port

Installing Optional Single - Stage Air Filter

An optional filter kit is recommended for improved fil-

tering with compressed air, to keep moisture and debris

out of the torch.

1. Attach the Single - Stage Filter Hose to the Inlet

Port.

2. Attach the Filter Assembly to the filter hose.

3. Connect the air line to the Filter. The illustration

shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the

fitting threads, according to the maker's in-

structions. Do Not use Teflon tape as a thread

sealer, as small particles of the tape may break

off and block the small air passages in the

torch. Connect as follows: