tekmar 421 Mixing Reset Module User Manual

Page 2

background image

© 2007

D 421 - 08/07

2 of 20

Table of Contents

Table of Contents ...........................................................2

Display and DIP Switches ..............................................2

Dip Switch Settings ................................................2

Access

Level

...........................................................3

Display and Symbols Description............................4

User Interface ........................................................5

Display Menus ................................................................6

View

Menu

..............................................................6

Adjust

Menu

............................................................7

Miscellaneous

Menu

...............................................9

Testing the Control .........................................................9

Sequence of Operation ................................................. 11

tekmarNet

®

4 Communication ............................... 11

Outdoor Reset ...................................................... 11

Mixing

Operation

.................................................. 13

Boiler Temperature Control .................................. 14

Boiler

Enable

......................................................... 15

Pump

Operation

................................................... 15

Pump

Exercising

................................................... 15

Error Messages ............................................................ 16

Troubleshooting ............................................................ 19

Warranty .......................................................................20

Set the DIP switch settings prior to making adjustments
to the control through the user interface. Setting the DIP
switches determines which menu items are displayed in
the user interface.

If you change a DIP switch setting while the control is
powered up, the LCD display returns to the View menu.

Lock / Unlock

Use the Lock / Unlock DIP switch to lock and unlock the Access
Level of the 421 and all connected tN4 devices, including
tN4 thermostats. For details, see “Access Levels”

• Once locked, the access level in all devices cannot be

viewed or changed.

• To determine if the control is currently locked a small

segment representing a padlock is viewed in the bottom
right hand corner of the display.

• To unlock the Access Level, set the DIP switch to

Unlock.

• To lock the Access Level, set the DIP switch to Lock.

Dip Switch Settings

Display and DIP Switches

51 52

55

56 57

Boiler

54

53

C

Com Boil Mix

Cls

Opn

58

R

R

59

Com Out

60

Variable Speed

2.5 A

7.5 A

max

61

62

N

Pump

tN4

Boil Sens Sup / Ret
Off / Flushing

Powered Output

Floating Output:

24 V (ac) 8 VA

Made in Canada

Meets Class B: Canadian
ICES & FCC Part 15

Test

Mixing Reset Module 421

Item

Menu

tektra 991-02

Var. Pump: 115V (ac) 2.5 A
Relay Rating: 115V (ac) 5 A

/

Do not apply power

System P1

63

64

N

Pump

Var. Pump Fuse

T2.5 A 250 V

H700

7B

Boil Sens Sup / Ret
Off / Flushing

/