Mount the Electrical Box
•
• Mount the electrical box securely in the location where the transformer is to be installed.
•
• Mount the transformer to the electrical box. Figure 1 shows how the transformer could be
mounted.
Basic Installation
The tekmar Transformer 009 is a 40 VA, 24 V (ac) transformer for use with products that require an external transformer.
The Transformer Kit 009K includes a 4" x 4" electrical J-Box.
Figure 1
When sizing a transformer it is important to know the load that it will be operating. Transformers are sized based on the VA
(Volt X Amps) power that they can provide. Use the sizing chart below to calculate the required VA. The tekmar Transformer
009 can supply a total of 40 VA. If the load exceeds 40 VA, a larger transformer is required.
Sizing the Transformer Load
Zone
1
2
3
4
5
6
Thermostat
Load
Zone Valve
Load
Other Load
Control
Load (VA)
Total Zone Load
+
+
+
+
+
+
Transformer
must exceed:
VA
•
• The high voltage side of the transformer can be determined by locating the two permanently connected, black and
black or black and white wires, which are factory-installed.
•
• Connect 120 V (ac) hot (L) to the black (L) wire on the transformer.
•
• Connect 120 V (ac) neutral (N) to the white or opposite black (N) wire on the transformer.
Low Voltage Side:
•
• The low voltage terminals have male spade connectors and are labelled R and C.
•
• Connect the red lead (with the in-line fuse) provided with the Transformer 009 to the R spade connector on the secondary
side of the transformer. The fuse is rated at 250 V (ac) 2.0 A slow-blow type.
• Connect the black lead provided with the 009 to the C spade connector on the secondary side of the transformer.
To avoid serious personal injury and damage to the equipment:
It is your responsibility to ensure that this product is safely installed according to all applicable codes and
standards. tekmar is not responsible for damages resulting from improper installation and/or maintenance.
•
• Read Manual and all product labels BEFORE using the equipment. Do not use unless you know the safe
and proper operation of this equipment.
•
• It is the installers responsibility to ensure that this product is safely installed according to all applicable codes
and standards.
•
• Ensure power to the circuit is off before wiring.
Wiring the Transformer
High Voltage Side: