Monitor Menu

The monitor menu allows you to view the following temperatures and running hours:

Outdoor temperature highs and lows
Room temperature highs and lows
Floor temperature highs and lows (requires floor sensor to be installed)
Filter Hours = Number of hours since the air filter was last replaced
Heat Y = Number of hours the heat pump is heating
Heat W = Number of hours the radiant floor (first stage heat) is on
Heat W2 = Number of hours the backup heat is on
Cool Y = Number of hours the heat pump is cooling
Cool W = Number of hours the radiant floor is actively cooling the room (available
in select radiant floor cooling installations)
Fan = Number of hours the fan has been operating
Humidify = Number of hours the humidifier is on
Dehumidify = Number of hours the dehumidifier is on

To clear the temperature highs and lows or the running hours:

1. Touch the temperature or running hours.

2. Display will show “

”.

3. Touch Enter.











Toolbox Menu

This menu is provides advanced level information.

Access

Change the access level on the thermostat.

Status Info
Displays the current status of the thermostat including any overrides from the tekmarNet

®

system control. Toggles between “Status Info” and the current status.

System Normal = Thermostat is operating normally.
For all other thermostat status messages, please see the Installation & Operation
Manual 553_D.

Software Version and Type Number

Display the software “SW” and the “TYPE” number.