tekmar 314 tN2 Wiring Center Installation User Manual
Installation & operation manual, D 314, Benefi ts
1 of 12
© 2011
D 314 - 05/11
tN2 Wiring Center 314
D 314
05/11
Zoning
Replaces: 11/10
Installation & Operation Manual
Power
Zone 1
Zone 2
Zone 3
Zone 4
End Switch
tN2 Wiring Center 314
Four Zone Pumps
For use with
tN2 thermostats only
tN2
Benefi ts
Simple, convenient wiring location
Compact enclosure for flexible installation
Reduce equipment cycling through the use of
tekmarNet
®
2 Thermostats
•
•
•
The tekmarNet
®
2 Wiring Center 314 is designed to operate up
to four zone pumps in a hydronic heating system. It provides a
convenient location to wire both thermostats and zone pumps
while only requiring two wires to be run back to the mechanical
room. When combined with tekmarNet
®
2 Thermostats, all
devices communicate to provide a synchronized end switch
that reduces cycling of equipment.
Features
Four 115 V (ac) powered zone outputs
For use with tekmarNet
®
2 Thermostats
Supports two-stage tekmarNet
®
2 Thermostats
tN4 expansion terminals
Isolated end switch
Outdoor sensor input
External diagnostic LEDs
CSA C US Certified for use in USA and Canada
•
•
•
•
•
•
•
•
Introduction
Notes
Not for use with tekmarNet
®
4 Thermostats
•