beautypg.com

Photogenic Professional Lighting Powerlight Manual (various) User Manual

Page 8

background image

Modeling Light:

The modeling light has three modes of operation:

1. MANUAL Press the ADJUST button to turn the MODEL yellow LED on. Adjust

the modeling lamp intensity using the 1/2 or 1/10 f-stops UP/DOWN arrow

buttons. Pressing the MANUAL button a second time will change the mode to

flash adjustment and is indicated by the illuminated red LED.

2. TRACK mode causes the modeling lamp intensity to track the FLASH setting.

The modeling lamp may be set to full intensity at any FLASH value, by simply

pressing the TRACK/SET button a second time, with the FLASH already set

to desired watt-seconds. Setting is retained when user returns from another

mode.

3. FULL ON/OFF. Press the FULL ON/OFF button to turn the modeling lamp OFF

(LED off) or ON (LED on) at full power.

All mode settings are retained, even after power has been turned off.

Test Function:

Press the TEST button to fire the flash tube for test purposes.

Flash Indication:

This function indicates the flash has fired properly. The flash indication feature will

dim the modeling light to its lowest setting, then intensify slowly to full brightness or

to its original state. This will occur after each flash, even though the modeling light

may be off. This feature is turned ON (LED on) or OFF (LED off) with the FLASH

INDICATION button.

Automatic Flash Dump:

This feature will automatically flash the unit when the FLASH setting is lowered;

otherwise, the internally stored power is discharged through a resistor, before the

unit is READY. Flash Dump is faster. This feature can be turned on or off, by the

user.

Turn FLASH DUMP on: Turn PowerLight AC power off. With unit power off, press

and hold the FULL ON/OFF button. While holding the FULL ON/OFF button,

turn the unit ON and wait until the FULL ON/OFF LED blinks. Release the FULL

ON/OFF button.

Turn FLASH DUMP off: Turn PowerLight AC power off. With unit power off, press

and hold the MANUAL button. While holding the MANUAL button, turn the unit

power on and wait until the MANUAL LED blinks. Next release the MANUAL

button and the MANUAL LED will go off.

Also, each time the AC line power is disconnected or switched off, the flashtube

will flash. This removes most of the flash capacitor charge to prolong the life of the

unit and is a much safer condition for storage, transporting, and replacement of