Power input, Circuit protection, Power switch – Photogenic Professional Lighting Powerlight Manual (various) User Manual
Page 5
POWERLIGHT MODEL PL1250
CONTROL PANEL AND BASIC OPERATION
Power Input:
The power required to operate the PowerLight 1250 is 105 to 125 volts AC, 60
Hz, 10 Amp. The power cord has a 125V, 10 Amp. rating. Replacement cords
or extension cords rated for less amperage may overheat and should not be used
with PowerLights.
Circuit Protection:
Circuit protection automatically protects this appliance from excessive damage
due to circuit or component failure. Operation exceeding the rated cycle of the
appliance may cause the fuse to open. (Always replace with same rating of fuse.)
An additional thermal protector is located inside the PowerLight and may open,
if the rated duty cycle is exceeded. A cooling off period of 10 to 45 minutes is
required to reset the thermal protector.
To replace a blown fuse (power cord must be disconnected), simply unscrew the
fuse holder cap (bottom of unit) and replace the exposed fuse with a new fuse.
If fuses continue to blow, contact your dealer or qualified service person. (See
specification section for fuse replacements).
Power Switch:
The power switch controls the AC power to both the modeling and flash circuits.
You have the option to turn-off the modeling circuit independently.
F
LASH
I
NDICATION
T
EST
O
N/
O
FF
R
EADY
F
LASH
M
ODEL
M
ANUAL
M
ADE IN
U.S.A.
S
LAVE
S
YNC.
T
RACK
S
ET
F
ULL
O
N/
O
FF
1/32 1/16 1/8 1/4 1/2
F
ULL
WARNING!
D
O NOT OPERATE
WITHOUT GLASS
LAMP COVER
IN PLACE.
Power Input
Connector
Optical Slave Sensor
Sync Outlet
Power Switch
Quick Change Levers
(Front of Light)
Umbrella Holder
Fuse Holder
Fan
Test Button
Modeling Lamp
Power Control
Ready Light
Flash Indication Button
Flash Power
Control
Modeling Lamp
Controls
Counterweight
Holder