OPERATIONAL PARAMETERS
Solair® PL500DR, PLR500DR,
Voltage Smart™ PLX500DR & PLXR500DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel.
A quick series of flashes can be obtained within the limits of the recharge time.
Continuous rapid flashing, however, can overheat and damage the flashtube and
internal parts. The maximum recommended rate of flashing depends upon the
power level being used and the amount of operation time. Use the following chart
to serve as a guide for the maximum rate to use in your situation.
Power
Level
Full
1/2
1/4
Operating
Time
Continuous
11 minutes
4 minutes
Continuous
4 minutes
1.4 minutes
Continuous
Sec. Between
Flashes
8.3
6
4
4
2
1
2
Number of
Flashes
Continuous
116
60
Continuous
124
85
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
Coverage
Full Power
1/2
1/4
1/8
1/16
1/32
1/64
1/128
32 inch
120 degree
5500
2750
1375
688
344
172
86
43
45 inch
120 degree
5583
2792
1396
698
349
174
87
44
60 inch
120 degree
5583
2792
1396
698
349
174
87
44
Reflector
Diameter
Coverage
Full Power
1/2
1/4
1/8
1/16
1/32
1/64
1/128
GN@ ASA 100/10’
None
360°
2333
1167
583
292
146
73
37
18
110
PL7R
7 1/2”
35°
25000
12500
6250
3125
1562
781
391
195
365
PL16R
16”
60°
23333
11667
5833
2916
1458
729
365
182
350
PL18R
18”
126°
3750
1785
892
446
223
112
56
28
137
PL24R
24”
145°
4200
2100
1050
525
262
131
66
33
150