OPERATIONAL PARAMETERS

PL2500DR, PLR2500DR, PLX2500DR and

PLXR2500DR

Flashing Rate:

The unit recharges quickly, as indicated by the READY light on the control panel.

A quick series of flashes can be obtained within the limits of the recharge time.

Continuous rapid flashing, however, can overheat and damage the flashtube and

internal parts. The maximum recommended rate of flashing depends upon the

power level being used and the amount of operation time. Use the following chart

to serve as a guide for the maximum rate to use in your situation.

1

Power

Level

Full

1/4

1/32

Operating

Time

Continuous

30 minutes

3 minutes

Continuous

30 minutes

3 minutes

Continuous

Sec. Between

Flashes

15

10

6

6

3

3

3

Number of

Flashes

Continuous

180

30

Continuous

600

60

Continuous

Exposure Information:

The following charts give the BCPS output for various umbrellas and reflectors.

Coverage angle is given in degrees.

Umbrella

Coverage

Full Power

Half

Quarter

Eighth

Sixteenth

Thirty-Second

32 inch

120 degree

11000

5500

2750

1375

688

344

45 inch

120 degree

11166

5583

2792

1396

698

349

60 inch

120 degree

11166

5583

2792

1396

698

349

Reflector

Diameter

Coverage

Full

Half

Quarter

Eighth

Sixteenth

Thrity-Second

GN@ ASA 100

None

360°

4666

2333

1167

583

292

146

160

7 1/2”

35°

50000

25000

12500

6250

3125

1562

515

18”

126°

7140

3570

1785

892

446

223

194

16”

60°

46666

23333

11667

5833

2916

1458

495

24”

145°

8400

4200

2100

1050

525

262

210