Power input, Flash power, Ready light – Photogenic Professional Lighting Powerlight Manual (various) User Manual
Page 14
14
SOLAIR POWERLIGHT MODELS PL500DRC,
PLR500DRC, PLX500DRC, PLRX500DRC, PL1000DRC,
PLR1000DRC, PLX1000DRC and PLRX1000DRC
CONTROL PANEL AND BASIC OPERATION
Power Input:
All PL and PLR model PowerLights will operate on 105 to 125 volts AC, 60 Hz, 10
amps. All PLX and PLRX Voltage Smart PowerLights will operate on 90 to 250 volts
AC, 50 to 60 HZ, 3.5 amps and have a 230 volt power cord with a German/
European plug. Replacement cords or extension cord rated for less amperage
may over heat, and should not be used with the above lights.
Flash Power:
Press the Adjust button to turn on the Flash ws digital display. Adjust the DR
PowerLight Flash power setting using the 1/2 or 1/10 f-stops UP/DOWN arrow
buttons.
Ready Light:
The DR PowerLights are fully charged when the READY lamp is on. For 1000
ws PowerLights the lowest power charge time is a maximum of .8 seconds, and
at full power charge time is a maximum of 3 seconds. For 500 ws PowerLights,
the lowest power charge time is a maximum of .5 seconds, and at full power the
charge time is a maximum of 1.5 seconds. The unit may be flashed before fully
charged.
Misfire Alarm
Auto-Bracket
(Press 3x)
A
DJUST
M
ADE IN
U.S.A.
S
LAVE
S
YNC.
T
RACK
S
ET
F
ULL
O
N/
O
FF
WARNING!
D
O NOT OPERATE
WITHOUT GLASS
LAMP COVER
IN PLACE.
F
LASH
M
ODEL
R
EADY
O
N/
O
FF
T
EST
F
LASH
M
ODEL
2
l
l
0
l
WS
WATTS
Power Input
Connector
Counterweight
Holder
Fuse
Holder
Optical Slave Sensor
Sync Outlet
Power Switch
Quick Change Levers
(Front of Light)
Digital Display
Umbrella Holder
Fan
Power Setting Buttons
Test Button
Flash/Modeling Lamp
Adjust Button
Ready Light
Flash On/Off LED
Modeling Lamp On/Off LED
Solair™
Constant Color PowerLight
®
PL1000DR