OPERATIONAL PARAMETERS

Solair® Constant-Color PL1000DR &

Voltage Smart™ Constant Color PLX1000DR

Flashing Rate:

The unit recharges quickly, as indicated by the READY light on the control panel.

A quick series of flashes can be obtained within the limits of the recharge time.

Continuous rapid flashing, however, can overheat and damage the flashtube and

internal parts. The maximum recommended rate of flashing depends upon the

power level being used and the amount of operation time. Use the following chart

to serve as a guide for the maximum rate to use in your situation.

Power

Level

Full

1/2

1/4

Operating

Time

Continuous

7 minutes

2.5 minutes

Continuous

4 minutes

1.4 minutes

Continuous

Sec. Between

Flashes

17

10

6

8.3

4

2
4

Number of

Flashes

Continuous

40

25

Continuous

60

43

Continuous

Exposure Information:

The following charts give the BCPS output for various umbrellas and reflectors.

Coverage angle is given in degrees.

Umbrella

Coverage

Full Power

1/2

1/4

1/8

1/16

1/32

1/64

1/128

32 inch

120 degree

11000

5500

2750

1375

688

344

172

86

45 inch

120 degree

111666

5583

2792

1396

698

349

174

87

60 inch

120 degree

111666

5583

2792

1396

698

349

174

87

Reflector

Diameter

Coverage
Full Power

1/2

1/4

1/8

1/16

1/32

1/64

1/128

GN@ ASA 100/10’

None

360°

4666

2333

1167

583

292

146

73

37

160

PL7R

7 1/2”

35°

50000

25000

12500

6250

3125

1562

781

391

515

PL16R

16”

60°

46666

23333

11667

5833

2916

1458

729

365

495

PL18R

18”

126°

7140

3750

1785

892

446

223

112

56

194

PL24R

24”

145°

8400

4200

2100

1050

525

262

131

66

210