Photogenic Professional Lighting Powerlight Manual (various) User Manual
Page 10
OPERATIONAL PARAMETERS
PL1250, PL1250DR, PLX1250DR,
PLR1250DR and PLXR1250DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel.
A quick series of flashes can be obtained within the limits of the recharge time.
Continuous rapid flashing, however, can overheat and damage the flashtube and
internal parts. The maximum recommended rate of flashing depends upon the
power level being used and the amount of operation time. Use the following chart
to serve as a guide for the maximum rate to use in your situation.
10
Power
Level
Full
1/4
1/32
Operating
Time
Continuous
30 minutes
3 minutes
Continuous
30 minutes
3 minutes
Continuous
Sec. Between
Flashes
15
6
4
6
3
2
1.5
Number of
Flashes
Continuous
300
45
Continuous
600
90
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
Coverage
Full Power
Half
Quarter
Eighth
Sixteenth
Thirty-Second
32 inch
120 degree
5500
2750
1375
688
344
172
45 inch
120 degree
5583
2792
1396
698
349
174
60 inch
120 degree
5583
2792
1396
698
349
174
Reflector
Diameter
Coverage
Full
Half
Quarter
Eighth
Sixteenth
Thrity-Second
GN@ ASA 100
None
360°
2333
1167
583
292
146
73
110
7 1/2”
35°
25000
12500
6250
3125
1562
781
365
18”
126°
3570
1785
892
446
223
112
137
16”
60°
23333
11667
5833
2916
1458
729
350
24”
145°
4200
2100
1050
525
262
131
150