beautypg.com

Kino Flo Blanket Light 6X6 DMX User Manual

Page 16

background image

16

WARNING!

1) ALWAYS TURN OFF THE

BALLAST BEFORE connecting
or disconnecting Lamps,
Harnesses or Extension Cables.

2) Use only with Sine wave inverters.

Do not operate on SCR dimmers.

3) If powering the ballasts through a

Dimmer Pack set the Dimmer to
Non-Dim Mode.

The 120 VAC Ballast requires 110 to 130 Volts AC 50/60 Hertz on an
earth grounded circuit; the 230 VAC Ballast requires 220 to 240 Volts
AC on an earth grounded circuit. The electronic Ballast operates at a
high frequency of 25 KHz. It is dead–quiet, instant–on and lightweight.

The Ballast operates remote from the fixture. Connect the Extension
cable to the Ballast and the Lamp Harness. After the lamps are
properly installed the Ballast can be turned on.

Cold Temperature Operation
The Select Ballast series is designed to operate at temperatures
from 14F to 122F (–10C to +50C). In cold temperatures, the Ballast
may not strike the lamp (s) instantly. Switch the Ballast to OFF, wait
seven seconds and try again. If the Ballast does not strike after two
or three attempts, turn off the Ballast, check that the Extension and
Harness connections are secure and re-strike. Once operating for a
few minutes, the Lamps should re-strike instantly.