Kino Flo Blanket Light 6X6 DMX User Manual
Page 14
![background image](/manuals/592415/14/background.png)
14
Setting the Ballasts to
"Fixture Mode" allows the
user to turn lamps on and
off with an “inside-out”
pattern from a dimmer
board.
For example: Blanket-Lites can be set to Fixture mode on a common address.
When the fader on the dimmer board is brought up or down all the Fixtures on
that address will have the same lamps turned on.
Dimmer level - Lamp response
Each ballast has 5 addresses. Addresses 001-004 control the lamps.
Sliding the fader on the dimmer board from 0 ~ 100 controls the number of lamps
that are on within a fixture. Address 005 controls the STD setting.
Note: The lamps may respond ± 4 channel levels, depending on the dimmer
board. To control the STD select feature, program the 5
th
address (005) at full.
Setting the dimmer value under 49% or not programming address 5 will restore
the HO setting.
To Control Light Levels from Multiple Blanket-Lites:
1) Set ballast to Fixture mode.
2) Set all ballast addresses to a common address (eg. 001).
3) Set address 005 if the STD setting is required.
4) Set end of line switch to “I” on the last unit in the DMX chain.