Operational Test and Start-up Diagnostics

Turn on Control Unit

• Plug Control Unit into grounded

110/120VAC electrical outlet (receptacle) .

• Toggle power switch to On position.
• The Control Unit display should read

“Fuser Found!”

• If the Control Unit display reads “Fuser

Error” alternating with “Check Fuser and

Cable Connection” then double check the

connections to ensure they are secure .

• The Fuser jaws must be closed to initiate

calibration . If the display reads “Please

Close Fuser Jaw” then close the Fuser

jaws by depressing fuser lever tongue .

• The Control Unit will chirp until the calibra-

tion process starts .

A

Fuser Button

NOTICE

BEFORE plugging Power Cord into

electrical outlet (receptacle) make

sure power (On/Off) switch is in Off

position.

Equipment Setup & Usage Instructions

Calibrate Fuser

• Depress Fuser Button as shown (A) for

approximately 2 seconds and release .

This allows the Control Unit to recognize

the Fuser’s size and profile .

• When ready the Control Unit display

ready button will turn green . When

ready the Control Unit display will read

“Fuser Ready to Start” alternating with

“Assemble Fitting & Attach Fuser .”

STEP 1

STEP 2