34

Tube Replacement

continued

– install new tube

1. By manually rotating the roller assembly

counter clockwise, align one of three
roller assembly slots with the suction side
housing slot.

2. Place tube fitting into suction side slot of

the housing and the roller assembly slot.
Illustration E

3. With pump setting on low, hold tube

fitting and jog roller assembly by turning
pump on.

IMPORTANT! Avoid rotating wrist, which can
result in a twisted tube that will not center. Do
not force tube and be careful of your fingers.

4. Guide tube, with slight tension (toward

the center) to prevent pinching between
housing and roller assembly. Illustration F

5. When tube reaches the top housing slot,

turn pump off.

6. Turn dial ring to setting 10, hold tube

fitting firmly, and turn pump on.

NOTE: A used tube will have stretched
approximately 3/4" and the new tube will
appear to be stiff and short. Follow directions
to allow rollers to stretch tube into place.

7. Allow rollers to stretch tube into place

while guiding tube into slot. Illustration G

8. Turn pump off.

9. Apply a small amount of grease

(AquaShield

®

) to cover bushing ONLY and

replace cover and two screws, leaving front
screw in-between the fittings loose.

INSTALL NEW TUBE

E

F

G

NOTE: Cover screws are self-tapping and must be
backed in to locate original thread before securing.
If a screw boss is stripped, use alternate bosses
and position opposite from each other. Never
secure the cover plate with more than 2 screws.

IMPORTANT! Do not lubricate