beautypg.com

Outputs 100 series – Watts T55-85MHP40 User Manual

Page 10

background image

www.stenner.com

10

Double Head

Maximum

Pump Tube

gallons

liters

gallons

liters

ounces

milliliters

liters

liters

milliliters

Model

Pressure

Number

per day

per day

per hour

per hour

per minute

per minute

per day

per hour

per minute

Adjustable

100DMHP5*

100 psi/6.9 bar

#1

0.3 to 6.0

1.1 to 22.7

0.01 to 0.25

0.05 to 0.95

0.03 to 0.53

0.76 to 15.76

0.9 to 18.2

0.04 to 0.76

0.61 to 12.64

100DM1

25 psi/1.7 bar

#1

Fixed Output

100DMPHP5*

100 psi/6.9 bar

#1

6.0

22.7

0.25

0.95

0.53

15.76

18.2

0.76

12.64

100DMP1

25 psi/1.7 bar

#1

Adjustable

100DMHP20*

100 psi/6.9 bar

#2

1.0 to 20.0

3.8 to 75.7

0.04 to 0.83

0.16 to 3.15

0.09 to 1.78

2.64 to 52.57

3.0 to 60.6

0.13 to 2.53

2.11 to 42.06

100DM2

25 psi/1.7 bar

#2

Fixed Output

100DMPHP20*

100 psi/6.9 bar

#2

20.0

75.7

0.83

3.15

1.78

52.57

60.6

2.53

42.06

100DMP2

25 psi/1.7 bar

#2

Adjustable

100DM3

25 psi/1.7 bar

#3

2.2 to 44.0

8.3 to 166.5

0.09 to 1.83

0.35 to 6.94

0.19 to 3.91

5.76 to 115.63

6.6 to 133.2

0.28 to 5.55

4.58 to 92.50

Fixed Output

100DMP3

25 psi/1.7 bar

#3

44.0

166.5

1.83

6.94

3.91

115.63

133.2

5.55

92.50

Adjustable

100DM4

25 psi/1.7 bar

#4

3.5 to 70.0

13.2 to 265.0

0.15 to 2.92 0.55 to 11.04 0.31 to 6.22

9.17 to 184.03

10.6 to 212.0

0.44 to 8.83

7.36 to 147.22

Fixed Output

100DMP4

25 psi/1.7 bar

#4

70.0

265.0

2.92

11.04

6.22

184.03

212.0

8.83

147.22

Adjustable

100DM5

25 psi/1.7 bar

#5

5.0 to 100.0

18.9 to 378.5

0.21 to 4.17 0.79 to 15.77 0.44 to 8.88

13.13 to 262.88

15.1 to 302.8 0.63 to 12.61 10.49 to 210.28

Fixed Output

100DMP5

25 psi/1.7 bar

#5

100.0

378.5

4.17

15.77

8.88

262.88

302.8

12.61

210.28

Approx. Outputs @ 60 Hz

Approx. Outputs @ 50 Hz

Outputs 100 series

NOTICE:

The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.

Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

*pump supplied with injection check valve for 26-100 psi applications

The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates

10% increments of maximum output. (20:1 Turndown Ratio)

0.3 to 6.0

1.1 to 22.7

0.01 to 0.25

0.05 to 0.95

0.03 to 0.53

0.76 to 15.76

0.9 to 18.2

0.04 to 0.76

0.61 to 12.64

6.0

22.7

0.25

0.95

0.53

15.76

18.2

0.76

12.64

1.0 to 20.0

3.8 to 75.7

0.04 to 0.83

0.16 to 3.15

0.09 to 1.78

2.64 to 52.57

3.0 to 60.6

0.13 to 2.53

2.11 to 42.06

20.0

75.7

0.83

3.15

1.78

52.57

60.6

2.53

42.06

This manual is related to the following products: