beautypg.com

Maintenance, Operation, Filter cartridge replacement procedure – Watts OFTWH User Manual

Page 4: Filter change frequency, Replacement filter cartridges

background image

4

Filter Cartridge Replacement Procedure

IMPORTANT: Determine whether all equipment connected to

the OneFlow

®

system must be turned off prior to shutting off

water supply from filters.

1. If required, turn off equipment.
2. Turn OFF water to OneFlow

®

system by closing

Inlet Ball Valve.

3. Press the red button to release pressure.
4. Remove housing(s) - use filter wrench if necessary.
5. Clean inside of housing sumps with warm water. If desired,

disinfect housing using a teaspoon of household bleach.

Add to filter bowl and add water. Let stand 5 minutes and

discard.

6. Insert new cartridge into filter housing. Match cartridge

model number to model number on bracket.

7. Make certain the O-ring is properly positioned and reinstall

filter housing (hand tighten only). Check O-ring for damage

and replace if damaged or distorted.

8. Slightly open the inlet ball valve; push the red pressure relief

button to release trapped air until a small amount of water

comes out - release the red button and fully open the ball

valve.

9. Open the flush valve downline from the filter housing (if

equipped) and flush the new cartridge to drain or bucket

for two (2) minutes or until water runs clear. If no flush valve

is present, disconnect line from equipment to flush to drain.

10.

VERY IMPORTANT: With water supply inlet valve OPEN

and water flow confirmed, turn on connected equipment.

Failure to supply water to equipment may cause serious

damage.

11. Record filter change on the service log.

Maintenance

Routine maintenance of your OneFlow

®

System involves periodic

filter cartridge changes and/or replacement of sump O-rings.

If the system sizing recommendations have been followed,

the OneFlow

®

Cartridge should last two years.

Filter Change Frequency

The filters should be changed in response to the following

conditions.
OFTWH-RM • 24 months since installation or last filter change.

Replacement Filter Cartridges

OneFlow

®

systems can only be used with OneFlow

®

filter

cartridges. Use of replacement cartridges other than those

specified will void warranties, certifications and may compromise

equipment protection, water quality and equipment life.

Operation

With sufficient pressure, operation of the Watts OneFlow

®

System is completely automatic. Dependable operation involves

only periodic filter changes and service documentation.

8.

4.

3.

2.

6.

7.