Installation drawings & dimensions – Watts OFTWH User Manual

Page 3

background image

3

Max Pressure: 90psi

Max Temperature: 100ºF

Wall

2'-

8"

Min.

5'-

0"

A.F

.F.

Installation

Height

1'-

9

7/8"

3 1/2"

5 1/8"

2

7/8"

to

inlet

3"

Min.

Remo

val

Clearance

Water filtration unit

must be installed on the

cold water supply only

Mounted to

secure wall

on studs or

wall panel –

Do not mount

to unsupported

sheet-rock

or gypsum board.

3/4" Full flow

ball valve inlet

connection to

water supply

Installation Drawings & Dimensions

3/4" MPT

adapter

req'd to

adapt to

FPT outlet

Max Pressure: 90psi

Max Temperature: 100ºF

3/4" MPT

adapter

req'd to

adapt to

FPT inlet

3/4" pipe or

3/4" I.D. flexible

reinforced

beverage tubing

from chlorinated

municipal water

supply

Water

Supply

Floor Line

Install – Min.–

3/4" full flow

ball valve

w/ 3/4" FPT

inlet connection

(Valve not incl'd)

2'-

8"

Min.

5'-

0"

A.F

.F.

Installation

Height

3"

Min.

Remo

val

Clearance

Water filtration unit

must be installed on the

cold water supply only

NOTE:

Do not mount filter

assembly behind ice

machine or other

appliances that would

impede access for

maintenance of

filtration system

Provide appropriate

pipe/tubing for

filtered and

treated water

to equipment