L-gage q50a, Analog output sensor, L-gage q50a analog output sensor specifications – Banner L-GAGE Q50 Series—Analog User Manual
Page 6

L-GAGE Q50A Analog Output Sensor Specifications
L-GAGE Q50A –
Analog Output Sensor
page
6
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Q50A: 50 to 200 mm (2" to 7.9")
Sensing Range
Linearity
Output Protection
Supply Voltage
15 to 30V dc (10% maximum ripple); 70 mA max. (exclusive of load)
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Delay at Power-up
2 seconds
Sensing Beam
Wave length
Q50AV: 685 nm (typical)
Q50A: 880 nm (typical)
Beam Size
Q50AV: 20 mm dia. (max.)
Q50A: 20 mm dia. (max.)
Output Configuration
Depending on model
4-20 mA current sourcing models: 1 k
Ω
max. load @ 24V dc. Max. load = [(Vcc -4.5)/0.02]
Ω
Loss of signal or target outside of sensor range: 3.6 mA
0-10V voltage sourcing models: 15 mA max.
Loss of signal or target outside of sensor range: 0V
Protected against short circuit conditions
Temperature Drift
Output Response Time
Analog Output
Average
Update
-3 dB Frequency
Interval
Rate
Response
Fast:
4 ms
1 ms
112 Hz
Slow:
64 ms
4 ms
7 Hz
±1.5 mm
Resolution
See Figure 3 for typical values
Target Distance: 100 mm
Slow Response: 0.5 mm max.
Fast Response: 2.0 mm max.
Color Sensitivity (typical)
See Figure 4
Q50AV: 50 to 150 mm (2" to 5.9")
From 0° to 50°C: 0.08 mm/°C
From -10° to 55°C: 0.11 mm/°C
Remote and Speed Input
Impedance
15 k
Ω
Remote Teach Input
To Teach:
Connect gray wire to +5 to 30V dc
To Disable:
Connect gray wire to 0 to +2V dc (or open connection)
Adjustments
Response Speed:
Fast Speed: Connect black wire to +5 to 30V dc
Slow Speed: Connect black wire to 0 to +2V dc (or open connection)
Indicators
Range LED
Green — Target is within sensing range
Indicator
Red — Target is outside sensing range
(green/red)
OFF — Sensor Power OFF
Teach/Output
Yellow — Target is within taught window limits
LED Indicator
OFF — Target is outside taught window limits
(yellow/red)
Red — Sensor is in TEACH mode
Minimum Taught Window
Model #
Ambient Light Immunity
<10,000 Lux
Distance
Q50A
Q50AV
5 mm
5 mm
10 mm
10 mm
15 mm
15 mm
20 mm
20 mm
25 mm
25 mm
–
35 mm
–
50 mm
50 mm
75 mm
100 mm
125 mm
150 mm
175 mm
200 mm