beautypg.com

Specifications – Banner VS1 Series User Manual

Page 3

background image

Specifications

Description

Feature

10 to 30V dc (10% maximum ripple) at less than 25 mA (exclusive of load)

Supply Voltage and
Current

Protected against reverse polarity and transient voltages

Supply Protection
Circuitry

SPST solid-state switch

Output Configuration

NPN (current sinking) or PNP (current sourcing), depending on model

Light operate (N.O.) or dark operate (N.C.), depending on model

50 mA maximum

OFF-state leakage current: < 1 microamp at 24V dc

Output Rating

ON-state saturation voltage: < 0.25V at 10 mA dc; < 0.5V at 50 mA dc

Protected against false pulse on power-up and continuous overload or short circuit of

outputs. Overload trip point

100 mA.

Output Protection
Circuitry

1 millisecond ON and OFF

Output Response Time

250 microseconds

Repeatability

Two LEDs: Green and Yellow

Green ON steady: sensor power ON

Indicators

Green flashing: output overload

Yellow ON steady: light is sensed

Yellow flashing: marginal excess gain (1-1.5x) in light condition

Black ABS/polycarbonate housing with clear acrylic lens

Construction

IP54; NEMA 3

Environmental Rating

2 m (6.5') attached cable: three #28 ga stranded conductors with PE insulation; PVC
outer cable jacket; or pigtail with 3-pin Pico-style quick-disconnect fitting. QD cables are
ordered separately.

Connections

Temperature: –20° to +55° C (–4° to +131° F)

Operating Conditions

Maximum Relative Humidity: 80% at 50° C (non-condensing)

M2 stainless steel mounting hardware included (see “Installation Notes”). Optional
mounting brackets are available (see

Accessory Mounting Brackets

on page 6).

Application Notes

Certifications

3

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

P/N _56465_ rev. D

VS1 Series