Setup mode, Manual adjust, Push button disable – Banner FI22 Expert Series User Manual
Page 7

P/N 108899 rev. C
FI22FP Low-Profile Inline Plastic Fiber Optic Sensor
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Figure 5. SETUP mode
SETUP
Status
Indicators
Press and
hold
both push
buttons > 2
seconds
to access
SETUP mode
{
SETUP Mode
SETUP mode is used to change sensor output response for:
• Light or Dark operate
• 30-millisecond pulse stretcher (OFF delay), if required.
The status LEDs, active only during SETUP mode, indicate the output response
configuration when the sensor will be in RUN mode. Four combinations are possible:
Light Operate, No Delay
Dark Operate, No Delay
Dark Operate, 30 ms Delay
Light Operate, 30 ms Delay
To access SETUP mode and change the output response settings:
1. Press and hold BOTH push buttons (or double-pulse Remote line) until the green LED
indicator turns OFF.
2. Click EITHER push button (or pulse Remote line) to toggle through the four possible
setting combinations.
3. Press and hold both push buttons (or hold Remote line) until the green LED indicator
turns ON, indicating return to RUN mode.
NOTES: • If SETUP mode programming is interrupted and remains inactive for 60
seconds, the sensor returns to RUN mode with the most recent settings
(i.e., exits and saves current selection).
• SETUP mode operates in the “background”, while the outputs are active.
Manual Adjust
Use during Run mode, accomplished via push buttons only.
Two-Point TEACH (Static or Dynamic):
• Fine-tunes sensing sensitivity
• Press “+” to increase; press “-” to decrease
Single-Point TEACH:
• Adjusts sensing window size (tolerance) for the single-point target condition
• Press “+” to increase; press “-” to decrease
The lighted bargraph LEDs move to reflect the increase or decrease.
Push Button Disable
In addition to its programming function, Remote Programming may be used to disable the
push buttons for security. Disabling the push buttons prevents undesired tampering with
the programming settings. Connect the gray wire of the sensor as described on page 9, and
four-pulse to either enable or disable the push buttons:
T
T T T
T
T
T
T
T
T
T
T
T
T
T