beautypg.com

World-beam, Qs30af adjustable-field sensor, Bar graph indicator functions – Banner WORLD-BEAM QS30 Series User Manual

Page 6: Setup mode, Push button disable

background image

WORLD-BEAM

®

QS30AF Adjustable-Field Sensor

6

P/N 111384 rev. D

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Bar Graph Indicator Functions

RUN Mode

• Lighted bargraph segment represents relative distance from the cutoff point.
All segments OFF: No object is detected within the visible range.

SET Mode

Segments 7 and 8 alternately flashing: Background Suppression SET is active
Segments 5 and 6 alternately flashing: Object Detection SET is active
Segments 1 and 8 alternately flashing: Dynamic SET is active

SET Mode Feedback

If the cutoff point is accepted, the sensor returns immediately to RUN mode. If the

taught cutoff point is beyond sensor range (closer than 50 mm or farther than

300 mm), the following are indicated for 2 seconds. (The sensor defaults to either

maximum or minimum cutoff, then returns to RUN mode.)
Segments 7 and 8 simultaneously flashing: Indiscernible target; either no target or

a highly reflective target (see page 7). Sensor defaults to maximum cutoff.

Segments 1 and 2 simultaneously flashing: Target is nearer than minimum cutoff.

Sensor defaults to minimum cutoff.

SETUP Mode

SETUP mode (accessible via push buttons only) is used to change sensor output

response for:
• Normally Closed or Normally Open operation
• 30-millisecond pulse stretcher (OFF-delay), if required
The status LEDs, active only during SETUP mode, indicate the output response

configuration when the sensor will be in RUN mode. Four combinations are possible:
Normally Open, No Delay

Normally Closed, No Delay

Normally Open, 30 ms Delay

Normally Closed, 30 ms Delay
To access SETUP mode and change the output response settings:
1) Press and hold BOTH push buttons simultaneously until the green LED indicator

turns OFF.

2) Click EITHER push button to toggle through the four possible setting

combinations.

3) Sensor returns to RUN mode after push buttons are inactive for 4 seconds.

NOTE: Outputs are active during SETUP mode.

Push Button Disable

In addition to its configuration function, the remote wire may be used to disable

the push buttons for security. Disabling the push buttons prevents accidental or

unauthorized adjustment of the sensor settings. Connect the gray wire of the sensor as

described on page 3, and four-pulse to either enable or disable the push buttons:

T

T T T

T

T

T

T

T

T

T

T

T

T

T

> 2 seconds

SETUP

Status

Indicators

{

Press and
hold
both push
buttons
to access
SETUP
mode

Figure 6. SETUP mode