L-gage, Lt3 long-range time-of-flight sensor, Two discrete outputs – Banner L-GAGE LT3 Series User Manual
Page 9: Specifications, cont’d

L-GAGE
®
LT3 Long-Range Time-of-Flight Sensor –
Two Discrete Outputs
P/N 68503 rev. C
9
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Specifications, cont’d
Construction
Housing: ABS
Window: Acrylic
Quick-disconnect: ABS/polycarbonate blend
Environmental Rating
IP67, NEMA 6
Connections
2 m (6.5') or 9 m (30') shielded 7-conductor (with drain) PVC-jacketed attached cable or 8-pin Euro-style
quick-disconnect
Operating Conditions
Temperature: 0° to +50°C (+32° to +122°F)
Maximum Relative Humidity: 90% at 50°C (non-condensing)
Application Notes
• Allow 30-minute warm-up before programming or operating (see Sensor Setup, page 2).
• Retroreflective performance specifications are based on use with BRT-TVHG-8X10P high-grade target.
Results may vary with other retroreflective target materials.
Certifications
Figure 7. LT3 repeatability (diffuse mode)
1
0
1
0
2
3
Distance (m)
Resolution/Repeatability vs. Distance
4
5
2
Resolution (mm)
3
4
5
6% Black
18% Gray
90% White
Fast
Medium
Slow
-30
-20
-10
0
10
20
-40
1
0
2
3
Distance (m)
Typical Color Sensitivity
4
5
Color Sensitivity (mm)
90% White to 18% Gray
90% White to 6% Black
Figure 8. LT3 color sensitivity (typical; diffuse mode)
Figure 9. LT3 repeatability (retroreflective mode)
2
4
0
10
0
20
30
Distance (m)
Repeatability vs. Distance
40
50
6
Repeatability (mm)
8
10
12
14
16
18
20
Fast
Medium
Slow