Attachment Examples for Aerial Installations

The top example shows a pretty

straightforward installation. The electric

meter is on the opposite side of the

building from the span, so attachment

near the the cold water tap is accept-

able.

The middle example shows that the

most direct route would trespass on

neighboring property. Therefore, the

drop should be run along the span

and then angle to the building, eventu-

ally running toward the meter and then

back to the point of entry. Be sure to

check mid-span; it is possible that there

may be a tap there because a pole

was there at one time.

The bottom example is a tough call.

It’s marginally shorter to attach near

the point of entry, run to the meter for

bonding purposes and double back to

the point of entry.

In all cases, check your local

code requirements and

system design specifications

for your prescribed

bonding requirements.

Planning the Run 4.2

Attachment Examples