3 configuration command string – Brady 1024 User Manual
Page 30

24
Printing Labels
2.3
Configuration Command String
The Configuration Command String sets the operating parameters of the
Printer. The Command Strings are described below.
where w:
Bit #
Function
Value
0-2
Baud Rate
0=9600, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A,
6=1200, 7=9600 Test Mode
3
Word Length
0=8 bits, 1=7bits
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where x:
Bit #
Function
Value
0
Print Method
0=direct, 1=transfer
1
Present Sensor
0=not equipped, 1=equipped
2
Alternate Char.
Set
0=standard, 1=main frame
3
Cutter
0=disabled, 1=enabled
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where y:
Bit #
Function
Value
0&1
Paper Type
0=gap(edge), 1=reflective, 2=continuous (3")
2
Linerless
0=not equipped, 1=equipped
3-5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
Example:
@
Sets the Printer to: 9600 baud; 8 bit word length/no parity.
A
Sets the Printer to: thermal transfer; no present sensor; standard
character set; no cutter.