Replacing Batteries

1. Disconnect the AC power cord from the ac mains supply.
2. Remove the four screws that secure the top cover.
3. Lift the top cover to access the attached ground wire then disconnect the

ground wire and remove the cover.

4. Unfasten the battery retaining belts then remove the battery tubes

(Figure 19). Be sure to note the polarity and orientation of the battery

tubes before removing them.

5. Remove the batteries from each tube and insert replacement batteries. Be

sure to note the polarity (positive and negative) arrangement of the batteries.

6. Install the battery tubes into the unit and secure with the retaining belts.

Be sure to position the retaining belts as they were before removal and

tighten them securely.

7. Connect the ground wire to the top cover.
8. Install the top cover and secure it with the four screws removed earlier.
Figure 19 Batteries

Long Term Storage
Do not store the instrument for long periods of time without recharging the bat-

teries. When the instrument is stored for long periods of time without use, the

batteries will loose their charge and also loose the ability to reach full charge

when put into service. To restore the battery charge, perform a full charge for 28

hours. If the batteries are not fully charged after 28 hours, completely discharge

the batteries then perform a full charge again. If necessary, repeat this dis-

charge and charge cycle up to three times. If the batteries do not remain

charged after three discharge-charge cycles, replace the batteries.

WARNING

Exposed AC line voltage (115 VAC or 230 VAC). Disconnect the power cord

from the AC line before replacing the batteries. Failure to comply may

result in severe electrical shock or death.

WARNING

Use only Nickel Metal Hydride (NiMH) batteries that have a minimum

capacity of 4500 milliamper hours (mAh). Do not install batteries that are

not Nickel Metal Hydride. Do not install NiMH batteries that have less than

4500 mAh capacity. Failure to comply may result in damage to the batteries,

damage to the instrument, and injury to personnel from battery chemicals.

Item

Description

1

Battery retaining belt

2

Battery tube (batteries inside)

X4

X4