Bird 8930 Series Termaline Coaxial Load Resistor

14

Leaking coolant

Loose clamping band

Tighten the clamping band

Defective or improperly
installed O-ring

Replace the O-ring

(see “Load Resistor” on page 18)

High or low dc
resistance

Loose RF input connector

Tighten connector

Faulty RF input connector

Model 8931: Replace connector

(see “RF Connector” on page 18)

All other models: Return the unit for service

Faulty resistor

Replace the resistor

(see “Load Resistor” on page 18)

Overheating radiator

RF power too high

Lower RF power (see “Specifications” on
page 23 for
maximum RF power)

Coolant level too low

Check the coolant level. Add coolant if
necessary (see “Coolant” on page 17)

Coolant degraded

Replace coolant (see “Coolant” on page 17)

Faulty control thermoswitch

Replace control thermoswitch

(see “Thermoswitch” on page 6)

Faulty resistor

Replace the load resistor

(see “Load Resistor” on page 18)

PROBLEM

POSSIBLE CAUSE

CORRECTION

Figure 7

Maintenance and Repair Locations