Chapter 5 maintenance, Troubleshooting, Chapter 5 – maintenance – Bird Technologies 8930 Series User Manual
Page 23: Maintenance
![background image](/manuals/583847/23/background.png)
13
Chapter 5
Maintenance
This chapter covers routine maintenance, troubleshooting,
specifications, and replacement parts for Bird 8930 Loads.
Troubleshooting
The table below contains troubleshooting information for problems
which can occur during normal operation. This manual cannot list all
malfunctions that may occur, or their corrective actions. If a problem
is not listed or is not corrected by the listed actions, notify a qualified
service center.
WARNING
Disconnect the unit from all power sources before servicing.
The unit may be energized from multiple sources.
The potential for electric shock exists.
WARNING
Never attempt to connect or disconnect RF equipment from the
transmission line while RF power is being applied.
Leaking RF energy is a potential health hazard.
PROBLEM
POSSIBLE CAUSE
CORRECTION
No air flow from
blowers; “BLOWER
ON” light off
Unplugged power cable
Connect the power cable
No ac power
Make sure ac power is properly connected
and turned on
Fuse burnout
Replace fuse after correcting the burnout
cause (see “Fuse” on page 19)
No air flow from
blowers; “BLOWER
ON” light on
Fan obstructed by bent grill
Straighten the grill
Fan motors overheated
Clean the grill and fan blades
Fan motors burnt out
Replace fan (see “Fans” on page 21)
Air flow from blowers;
“BLOWER ON” light off
Lamp burnout
Replace lamp