Page 23: Maintenance

background image

13

Chapter 5

Maintenance

This chapter covers routine maintenance, troubleshooting,
specifications, and replacement parts for Bird 8930 Loads.

Troubleshooting

The table below contains troubleshooting information for problems
which can occur during normal operation. This manual cannot list all
malfunctions that may occur, or their corrective actions. If a problem
is not listed or is not corrected by the listed actions, notify a qualified
service center.

WARNING

Disconnect the unit from all power sources before servicing.

The unit may be energized from multiple sources.

The potential for electric shock exists.

WARNING

Never attempt to connect or disconnect RF equipment from the

transmission line while RF power is being applied.

Leaking RF energy is a potential health hazard.

PROBLEM

POSSIBLE CAUSE

CORRECTION

No air flow from
blowers; “BLOWER
ON” light off

Unplugged power cable

Connect the power cable

No ac power

Make sure ac power is properly connected
and turned on

Fuse burnout

Replace fuse after correcting the burnout
cause (see “Fuse” on page 19)

No air flow from
blowers; “BLOWER
ON” light on

Fan obstructed by bent grill

Straighten the grill

Fan motors overheated

Clean the grill and fan blades

(see “Cleaning” on page 15)

Fan motors burnt out

Replace fan (see “Fans” on page 21)

Air flow from blowers;
“BLOWER ON” light off

Lamp burnout

Replace lamp

(see “Indicator Light” on page 19)