1. Reassemble the duplexer by reinstalling the cav-

ities and interconnect cables in their original
locations.

2.

The passband for the channels are fine tuned
first, in a manner very similar to tuning a single
cavity.

3.

A zero reference for return loss must be estab-
lished at the IFR-7550. Connect the RLB to the
analyzer / generator as shown in figure 3.

4.

Set-up the analyzer / generator to the desired
frequency (center of display) and for a vertical
scale of 10 dB/div.

5.

Do not connect the RLB to the duplexer at this
time, leave the "load" port on the bridge open.
This will supply the maximum amount of
reflected energy to the analyzer input.

6.

Insure that the IFR A-7550 menu's are set as
follows:
DISPLAY - line
MODE - live
FILTER - none
SETUP - 50 ohm/dBm/gen1.

7.

The flat line across the screen is the return
loss curve. Select the "MODE" main menu item
and then choose the "STORE " command.

8.

Next select the "DISPLAY" main menu item
and choose the "REFERENCE" command.
This will cause the stored value to be displayed
at the center of the screen as the 0 dB refer-
ence value.

9.

Connect the "load" port on the RLB to the
equipment port of the channel to be fine tuned.
Terminate the duplexers antenna connector
with the 50 ohm load. The equipment port of
the remaining duplexer channel is left discon-
nected, refer to Figure 6.

10. The display will now present the combined

return loss curve for all of the cavities in the
channel. The channels passband is that fre-
quency range over which the return loss is 15
dB or greater.

11. Fine tune the passband (for maximum return

loss) for the entire channel by gently adjusting
the positions of the tuning rods, moving
between cavities as required. Once the desired
response is obtained "lock" the tuning rods into
place by tightening the 1/4" shaft lock nuts on
each filter.

12. Move the cable from the RLB's "load" port to

the equipment port of the other channel. This
will allow the remaining duplexer channel to be
fine tuned. Reset the analyzer / generator cen-
ter frequency. Repeat steps 10 and 11.

GENERATE

OUTPUT

ANALYZER

INPUT

10

0

-10

-20

-30

-40

-50

-60

-70

dBm

40

0

10

300

dB ATT

GEN

dBM

MSEC

KHz RES

KHz/DIV

500

MHz

4" DIAMETER

VARI-NOTCH

FILTER

Figure 5: Checking the rejection notch.