APPENDIx C: UDS Codes and their Bendix Blink Code Equivalents
UDS
Code
US-
Spec .
Blink
Code
J1587
PID194
(SID/
FMI)
J1939/73
DM1/2
SPN/FMI
DTC Description
Lamp
Status
ABS
ATC/
ESP
201 15-06
006-08
0794-08
AA Right WSS Erratic Sensor Signal
ON
ON
202 15-04
006-10
0794-10
AA Right WSS Loss of Sensor Signal
ON
ON
205 20-03
066-05
1056-05
Trailer PMV REL Solenoid Open Circuit
-
ON
206 20-01
066-04
1056-04
Trailer PMV REL Solenoid Shorted to Ground
-
ON
207 20-02
066-03
1056-03
Trailer PMV REL Solenoid Shorted to Voltage
ON
ON
209 12-06
023-02
0811-02
ABS Indicator Lamp Circuit
ON
-
210 12-10
079-13
1069-13
Tire Size Out of Range (Front to Rear)
ON
ON
212 12-11
022-07
0810-07
Wheel Speed Sensors Reversed on an Axle
ON
ON
213 12-01
055-07
1045-07
Stop Lamp Switch Not Detected
-
ON
214 12-03
017-14
0576-14
ATC Disabled or Dynamometer Test Mode Active
-
ON
216 12-02
055-02
1045-02
Stop Lamp Switch Defective
ON
ON
220 12-13
102-03
0564-03
Diff Lock Solenoid Shorted to Voltage (total shutdown)
ON
ON
221 12-12
102-05
0564-05
Diff Lock Shorted to Ground or Open Circuit
ON
-
225 16-06
046-05
0799-05
AA Left PMV HLD Solenoid Open Circuit
ON
ON
226 16-04
046-04
0799-04
AA Left PMV HLD Solenoid Shorted to Ground
ON
ON
227 16-05
046-03
0799-03
AA Left PMV HLD Solenoid Shorted to Voltage
ON
ON
228 16-07
011-05
0799-05
AA Left PMV CMN Open Circuit
ON
ON
229 16-03
052-05
0799-05
AA Left PMV REL Solenoid Open Circuit
ON
ON
230 16-01
052-04
0799-04
AA Left PMV REL Solenoid Shorted to Ground
ON
ON
231 16-02
052-03
0799-03
AA Left PMV REL Solenoid Shorted to Voltage
ON
ON
232 11-13
231-02
0639-02
timeout or invalid data on J1939 AWD params for ESP AWD
operation
-
ON
237 16-08
011-13
0799-13
AA Left PMV Configuration Error
ON
ON
238 13-26
155-14
0615-14
Maximum number of PCV cycles reached
-
-
239 13-27
155-14
0615-14
Maximum number of TCV cycles reached
-
-
240 23-01
099-02
1809-02
LAS Signal Out of Range
-
ON
241 17-06
047-05
0800-05
AA Right PMV HLD Solenoid Open Circuit
ON
ON
242 17-04
047-04
0800-04
AA Right PMV HLD Solenoid Shorted to Ground
ON
ON
243 17-05
047-03
0800-03
AA Right PMV HLD Solenoid Shorted to Voltage
ON
ON
244 17-07
012-05
0800-05
AA Right PMV CMN Open Circuit
ON
ON
245 17-03
053-05
0800-05
AA Right PMV REL Solenoid Open Circuit
ON
ON
246 17-01
053-04
0800-04
AA Right PMV REL Solenoid Shorted to Ground
ON
ON
247 17-02
053-03
0800-03
AA Right PMV REL Solenoid Shorted to Voltage
ON
ON
248 23-04
099-02
1809-02
LAS Long Term Calibration Error
-
ON
249 23-03
099-02
1809-02
LAS Static Calibration Error
-
ON
250 23-05
099-02
1809-02
LAS Plausibility Error (Inside Model Based Limits)
-
ON
251 23-06
099-02
1809-02
LAS Plausibility Error (Outside Model Based Limits)
-
ON
253 17-08
012-13
0800-13
AA Right PMV Configuration Error
ON
ON
SD-13-4869_US_003 © 2013 Bendix Commercial Vehicle Systems LLC • All Rights Reserved • 6/13