Bendix Commercial Vehicle Systems EC-60 ESP CONTROLLERS ADV User Manual
Page 56
56
APPENDIx C: UDS Codes and their Bendix Blink Code Equivalents
UDS
Code
US-
Spec .
Blink
Code
J1587
PID194
(SID/
FMI)
J1939/73
DM1/2
SPN/FMI
DTC Description
Lamp
Status
ABS
ATC/
ESP
0
01-01
000-00
---
no DTC
-
-
1
14-03
005-02
0793-02
AA Left WSS Open or Shorted
ON
ON
3
14-10
005-13
0793-13
AA Left WSS Configuration Error
ON
ON
4
13-14
254-12
0629-12
ECU (04)
ON
ON
5
14-05
005-07
0793-07
AA Left WSS Wheel End
ON
ON
6
13-15
254-12
0629-12
ECU (06)
ON
ON
7
14-01
005-01
0793-01
AA Left WSS Excessive Air Gap
ON
ON
8
14-02
005-14
0793-14
AA Left WSS Output Low @ Drive-Off
ON
ON
9
14-06
005-08
0793-08
AA Left WSS Erratic Sensor Signal
ON
ON
10
14-04
005-10
0793-10
AA Left WSS Loss of Sensor Signal
ON
ON
13
13-17
254-02
0629-02
ECU (0D)
ON
ON
14
13-16
254-12
0629-12
ECU (0E)
ON
ON
15
12-14
103-02
1808-02
Sensor CAN Supply Voltage Error
-
ON
16
13-02
254-12
0629-12
ECU (10)
ON
ON
17
13-03
254-12
0629-12
ECU (11)
ON
ON
18
13-04
254-02
0629-02
ECU (12)
ON
ON
19
13-05
254-02
0629-02
ECU (13)
ON
ON
20
13-06
254-12
0629-12
ECU (14)
ON
ON
21
13-07
254-02
0629-02
ECU (15)
ON
ON
22
13-08
254-13
0630-13
ECU (16)
ON
ON
23
13-09
254-13
0630-13
ECU (17)
ON
ON
24
13-10
254-12
0630-12
ECU (18)
ON
ON
25
13-18
254-02
0629-02
ECU (19)
ON
ON
26
13-11
254-12
0802-12
ECU (1A)
ON
ON
27
13-12
254-12
0802-12
ECU (1B)
ON
-
28
13-19
253-12
0630-12
ECU (1C)
-
-
29
13-21
253-13
0630-13
ECU (1D)
ON
ON
30
13-22
253-13
0630-13
ECU (1E)
ON
ON
32
06-06
251-03
0627-03
Ignition Voltage Too High
ON
ON
33
06-05
251-04
0627-04
Ignition Voltage Too Low
ON
ON
34
06-07
251-04
0627-04
Ignition Voltage Too Low During ABS
ON
ON
35
06-02
251-03
0627-03
Battery Voltage Too High
ON
ON
36
06-01
251-04
0627-04
Battery Voltage Too Low
ON
ON
37
06-03
251-04
0627-04
Battery Voltage Too Low During ABS
ON
ON
38
06-04
251-05
0627-05
Battery Voltage Input Open Circuit
ON
ON
39
13-20
253-12
0630-12
ECU (27)
ON
ON
40
13-23
253-13
0630-13
ECU (28)
ON
ON
41
12-08
093-03
0802-03
PMV Common Shorted to Voltage
ON
ON
42
12-07
093-04
0802-04
PMV Common Shorted to Ground
ON
ON
43
11-07
231-02
0639-02
Timeout or invalid CAN data for ETC7/VP15
-
-
44
11-04
231-02
0639-02
J1939 Invalid Data (Engine/Retarder)
-
ON
45
11-05
231-02
0639-02
J1939 Supply Pressure
-
ON
46
11-08
231-02
0639-02
Timeout or invalid CAN data - XBR
-
-