APPENDIx B: J1587 SID and FMI Codes and their Bendix Blink Code Equivalents
SID
(J1587)
SPN
(J1939)
FMI
(J1587/
J1939)
Bendix Blink Code
Equivalent(s)
Diagnostic Trouble Code Description
(1st Digit) (2nd Digit)
Miscellaneous DTCs
55
1045
2
12
2
Stop Lamp Switch Defective
55
1045
4
12
27
Brake Lamp Input Mismatch with Brake Lamp Output
55
1045
7
12
1
Stop Lamp Switch Not Detected
Pressure Modulator Valve DTCs
66
1056
3
20
2
Trailer PMV REL Solenoid Shorted to Voltage
66
1056
3
20
5
Trailer PMV HLD Solenoid Shorted to Voltage
66
1056
4
20
1
Trailer PMV REL Solenoid Shorted to Ground
66
1056
4
20
4
Trailer PMV HLD Solenoid Shorted to Ground
66
1056
5
20
3
Trailer PMV REL Solenoid Open Circuit
66
1056
5
20
6
Trailer PMV HLD Solenoid Open Circuit
66
1056
5
20
7
Trailer PMV CMN Open Circuit
66
1056
7
20
8
PMV Configuration Error
For more Pressure Modulator Valve DTCs - see SID 93 below...
Brake Demand/Load Sensor DTCs
69
1059
2
24
3
Open or Shorted Load Sensor
77
1067
2
24
1
Shorted Brake Demand Sensor (Primary CKT) Open
77
1067
2
24
5
PS Supply Voltage Error
77
1067
7
24
6
PS Not Calibrated
77
1067
11
24
4
Plausibility Error Brake Demand Sensor
78
1068
2
24
2
Shorted Brake Demand Sensor (Secondary CKT) Open
Miscellaneous DTCs
79
1069
13
12
10
Tire Size Out of Range (Front to Rear)
Steering Angle Sensor DTCs
89
1807
2
21
3
SAS Static Signal
89
1807
2
21
4
SAS Signal Out of Range
89
1807
2
21
5
SAS Signal Reversed
89
1807
2
21
7
SAS Gradient Error
89
1807
2
21
9
SAS Long Term Calibration Error
89
1807
2
21
10
SAS Plausibility Check (Ref Yaw Rate)
89
1807
9
21
8
SAS CAN Timeout
89
1807
12
21
6
SAS Invalid Signal
89
1807
13
21
1
SAS Not Calibrated
89
1807
13
21
2
Steering Angle Sensor Calibration Not Finished
89
1808
13
22
15
YRS Sign Check Not Finished
Pressure Modulator Valve DTCs
93
802
3
12
8
PMV Common Shorted to Voltage
93
802
4
12
7
PMV Common Shorted to Ground
HSA DTCs
94
2622
2
12
4
HSA lamp shorted to ground or broken wire
94
2622
3
12
5
HSA lamp shorted to Voltage
94
2622
3
12
24
HSA solenoid shorted to Voltage (total shutdown)
94
2622
3
12
26
HSA solenoid shorted to Voltage (ATC & ESP shutdown)
94
2622
5
12
25
HSA solenoid shorted to ground or broken wire
94
2622
13
12
24
HSA solenoid shorted to Voltage
Lateral Acceleration Sensor DTCs
99
1809
2
23
1
LAS Signal Out of Range
99
1809
2
23
3
LAS Static Calibration Error
99
1809
2
23
4
LAS Long Term Calibration Error
99
1809
2
23
5
LAS Plausibility Error (Inside ECU-Specific Limits)
99
1809
2
23
6
LAS Plausibility Error (Outside ECU-Specific Limits)
99
1809
13
23
2
LAS Calibration in Progress
99
1808
14
23
7
Erratic ESP Sensor Signal