Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual
Page 35

PAGE 35 TP10476-1
6.2 Run Time Fault Messages
Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors or
errors in the whole electric system. It is necessary to call an technician or service.
English
German
Codes
TYPE
DESCRIPTION
DCT
DCT
DCT
Information
This is the Software-Version(X.X.X)
X.X.X
X.X.X
X.X.X
Note:do not push any buttons until this message has been
cleared from the display
K5 Relay
K5 Relay
Error 7
PLC System
The drive stop relay, K5, is not responding to the controller.
Error
Action: Call service.
Button
Taste
Error 8
Electric
A push button is in the wrong state during the version
System Error
message display.
Action: Check Buttons & Cycle Power. If error persists call
service
Watchdog
Watchdog
Error 9
PLC System
The Watchdog Timer has elapsed without being serviced.
Error
Action: Cycle Power. If error persists call service
No Tach
Impuls
Error10
Electric
The Machine Tachometer is reading a velocity outside of the
System Error
range 10 – 230 meters per minute, while the main drive
should be running.
Action: Check the electric. If error persists call service.
Overload
Uberlast
Error11
Electric
A Thermal Overload has been tripped.
System Error
Action: Check the electric. If error persists call service
Pile Err
Spg. Uber
Error12
Electric
The Pile Safety Relay is stuck on or there is no power supply to
System Error
the pile circuits.
Action: Check the condition of Relay 1 K1, Fuses F1 and F2,
and X18, then cycle Power. If error persists call service
Overrun
Uberlauf
Error13
Electric
The Pile Table has moved past its safety stops.
System Error
Action: Check the limit switches, pile table, and wiring. If error
persists call service
2nd Stat
2Station
Error14
Electric
The Emergency Stop, Wrong Sheet, and Thermal Overload
System Error
sense circuits are all indicating failure. Likely cause is Second
Station connector problems.
Action: Check the Second Station Connector, connector X22,
and each individual circuit. If error persists call service
Suction
Saugtakt
Error15
Electric
Short circuit on Suction controller.
System Error
Action: Check the electric. If error persists call service
CLR Stop
CLR Stop
Error16
Electric
Emergency Stop activated during power-up sequence
System Error
ERROR 17
ERROR 17
Error17
Electric
Incorrect check-back signal received from K2 protective relay.
System Error
Power-up sequence (Check-back contact)
ERROR 18
ERROR 18
Error18
Electric
Incorrect check-back signal received from K2 protective relay.
System Error
Shutdown sequence (Check-back contact)
Table 19. Run Time Fault Messages