Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual
Page 30

TP10476-1
PAGE 30
3. Controller Input Description
3.1 Table Inputs
Input
Type
Connector Point
Indicator
Name
DCI-1
NPN 24VDC
X14/2
P31.1
Pile Sensor
DCI-2
NPN 24VDC
X14/5
P14.8
Photoeye Suction Wheel
DCI-3
PNP 24VDC
X25/5
P32.7
Delivery Count Input
DCI-4
NPN 24VDC
X15/2
LED 1
Encoder
DCI-5
NPN 24VDC
X26/1
P32.5
Sheet Control Knife 1
DCI-6
NPN 24VDC
X26/2
P32.4
Sheet Control Knife 2
DCI-7
NPN 24VDC
X26/4
P32.3
Knife Manual
DCI-9
PNP 24VDC
X26/8
P32.1
Ergonomic Pile Make Ready
DCI-10
24VDC
X30/5
P34.3
Light sensor - Folding station del.
DCI-11
24VDC
X30/11
P34.2
Folding station - Make Ready
ACI-1
24VAC
X21/1, X21/2, X23/3
P30.8
Drive is on
ACI-2
24VAC
X11/3, X22/2, X23/4
P31.8
Emergency Stop/Drive Stop
ACI-3
24VAC
X22/3
P31.7
Jammed Sheet
ACI-4
24VAC
X22/4
P31.6
Drive Thermal Fault
ACI-5
24VAC
X21/5, X23/9
P31.5
Sheet Stop Button
ACI-6
24VAC
X21/6, X23/11
P31.4
Sheet Start Button
ACI-7
24VAC
X11/2
P31.3
Pile is down
ACI-8
24VAC
X11/6
P31.2
Double Sheet Fault
ACI-9
24VAC
X23/5
P30.7
Compressor Start Button
ACI-10
24VAC
X23/6
P30.6
Compressor Stop Button
ACI-11
24VAC
X23/10
P30.4
Pile Stop Button
ACI-12
24VAC
X23/12
P30.3
Pile Down (backward) Button
ACI-13
24VAC
X23/14
P30.5
Pile Up (forward) Button
ACI-14
220VAC
Internal
P30.2
Function Control K1
ACI-15
220VAC
Internal
P30.1
Function Control Pile
ACI-16
24VAC
X29/5
P34.5
K2 protective relay monitor
ACI-17
24VAC
X29/7
P34.4
External device monitor
ACI-18
24VAC
X29/1
P34.8
Emergency stop - control panel
ACI-19
24VAC
X29/2
P34.7
Emergency stop - guard
ACI-20
24VAC
X29/3
P34.6
Emergency stop - next stations
ACI-24
24VAC
X19/2
P34.1
External mis-fed sheet
Table 15. Inputs
3.2 24VAC Inputs
Several mechanical switches are used to indicate machine
faults. These faults are described here. If these faults occur
when the machine is not running, they will display the
associated fault message until the fault is cleared. The only
exception is the Safety fault. The Safety fault always
requires removal of power before the machine can be used
again. If a fault occurs while the machine is running, the
method used to clear the fault varies from fault to fault.
Double Sheet
The Double Sheet switch is used to sense multiple sheets
being fed into the machine at the same time. If this fault occurs,
the message “2 Sheet” will be displayed and sheet feeding will
stop. The Drive and Compressor outputs will continue
unaffected. Once the fault has been cleared the machine can
start feeding sheets again by pressing the Sheet Start switch.