Table 4 machine diagnostic mode parameters – Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual
Page 23

PAGE 23 TP10476-1
P23: Pause
This function is used to activate/deactivate a Pause counter. Select this parameter to display the period of time
for which the pause function was last engaged. It is not possible to feed in sheets when the Pause function is
activated.
P24: Network
Network is only displayed when "Network" is selected and enabled in the Service menu. Not available in
Software Version 100.300.
P25:Easy Mode
This function can only be used on machine types P-b20, C-b20, C-2020 and P-2020.
P26:Hardware and Firmware Version
Select this parameter to display the software installed in Service mode. The logic board type appears in the left
of the display. DCT displays a DCT 500 logic board.
P27:Machine Type
Select this parameter to view the Machine type specified in Service mode.
P28:Serial Port
Parameter setting in Service mode is displayed: dSp, nEt, Off
P30
Status Input Port 1
P30.1
P30.2
P30.3
P30.4
P30.5
P30.6
P30.7
P30.8
Pile Motor
Function
Pile Down
Pile Stop
Pile Up
Compress.
Compress.
Drive Start
Energized
Control K1
Button
Button
Button
Stop Button
Start Button
Relay K3
P31
Status Input Port 2
P31.1
P31.2
P31.3
P31.4
P31.5
P31.6
P31.7
P31.8
Pile Sensor
Double
Pile Down
Sheet Start
Sheet Stop
Thermal
Wrong Sheet
Emerg.Stop
Sheet Fault
Limit
Button
Button
Fault
Fault
Drive Stop
Button
P32
Status Input Port 3
P32.1
P32.2
P32.3
P32.4
P32.5
P32.6
P32.7
P32.8
Ergonomic
Jam on
Knife in
Jam on
Jam on
Suction
Delivery
Count sensor
Pile Load
Knife 3
Manual Mode Knife 2
Knife 1
Controller
Count Input
Suction
Eye
fail
Wheel
P33
Status Input Port 4
P33.1 N
P33.2
P33.3
P33.4
P33.5
P33.6
P33.7
P33.8
Board select
Board select
Not used
Not used
Not used
Not used
Not used
Not used
P34
Status Input Port 5
A34.1
A34.2
A34.3
A34.4
A34.5
A34.6
A34.7
A34.8
External
Setup
LT folding
External
K2 Checkback Emerg. stop
Emerg. stop
Machine
Mis-feed sht. Station 2
station
device
signal
station
guard open
Emerg. stop
delivery
protection
activated
P35
Status Output Port 1
P35.1
P35.2
P35.3
P35.4
P35.5
P35.6
P35.7
P35.8
Not used
Controller
Relief
Not used
Pile down
Pile up
Drive Stop
Pump
drive
valve/Tremat
active
is active
function
start (K4)
release
ON (K6)
Relay (K5)
Table 4 Machine diagnostic mode parameters