PAGE 24
P30: Port 1 Inputs
P30 indicates Port 1 input status.
P31: Port 2 Inputs
P31 indicates Port 2 input staus
P32: Port 3 Inputs
P32 indicates Port 3 input status
P33: Port 4 Inputs
P33 indicates Port 4 input status
P34:Port 5 Inputs
P34 indicates Port 5 input status
P35: Port 1 Outputs
P35 indicates Port 1 output status
Table 5 Safety settings
#
Function
Operation
Key Combin.
Variable Displayed
P60
Drive start key delay
Adjustable with
0 - 13 secs.
P61
K2 release time
Adjustable mit RP2 Adjuster-
K2 Delayed release (sec)
(large display)
+
P60: Drive Start Delay period (only when A02=0)
Entering the Drive Start Delay period for Station 1 (Settings: 0 to 13.0 sec.) ensures that the paper runs
smoothly after starting if there is any paper still inside the machine. (Station 1: approx. 0.6 sec.)
P61: Display of delayed release for the K2 guard (only when A02=0)
Adjuster for setting the K2 delayed release (Measuring time = 0 to 10 sec.). Adjust with the RP2 poti on the
SGM-3 board. Default setting = approx. 2.5 sec.
#
Function
Type
Variable Displayed
P40
Mon. time for Knife 1
Variable function
Input X26/1, P32.5
Time in milliseconds
P41
Mon. time for Knife 2
Variable function
Input X26/2, P32.4
Time in milliseconds
P42
Folding station delivery
Variable function
Input X30/5, P34.3
Time in milliseconds
P43
Counting input
Variable function
Input X25/5, P32.7
Time in milliseconds
P44
Knife 1 strokes
Variable function
Input X26/2, P32.4
Time in milliseconds
P45
Knife 2 strokes
Variable function
Input X26/5, P32.2
Time in milliseconds
P40: Time: Knife 1
Knife 1: Light sensor cover time in milliseconds.
P41: Time: Knife 2
Knife 2: Light sensor cover time in milliseconds.
Table 6 Machine statistics