Hapter, Modifying the drive configuration – Rockwell Automation FlexPak 3000 Drive Field Current Regulator Kit, 911FK0041, 911FK0101, 911FK015 User Manual
Page 31

Modifying the Drive Configuration
5-1
C
HAPTER
5
Modifying the Drive Configuration
Before you can use the Field Current Regulator kit, you must set the parameters listed
below in the FlexPak 3000 drive. These parameters are described in sections 5.1 and
5.2.
•
Parameter 510 (
MOTOR
HOT
FLD
AMPS
)
•
Parameter 511 (
FIELD
ECONOMY
REF
)
In addition, the input parameters listed below may need to be adjusted in order to tune
the field control loop. Refer to your drive’s instruction manual for a complete
description of these parameters.
•
Parameter 501 (
FIELD
ECONOMY
DELAY
)
•
Parameter 512 (
FIELD
LOSS
THRESHOLD
)
•
Parameter 513 (
FIELD
REF
REGISTER
)
•
Parameter 514 (
FIELD
PI
PROP
GAIN
)
•
Parameter 515 (
FIELD
PI
LEAD
FREQ
)
•
Parameter 516 (
FLD
FEEDBACK
GAIN
ADJ
)
•
Parameter 517 (
FIELD
AUTO
WEAKEN
)
•
Parameter 518 (
FLD
WEAKEN
THRESHOLD
)
•
Parameter 519 (
FLD
WEAKEN
PROP
GAIN
)
•
Parameter 520 (
FLD
WEAKEN
LEAD
FREQ
)
•
Parameter 587 (
FIELD
DELTA
HIGH
LIM
)
•
Once the Field Current Regulator kit is installed and the drive is configured, the
following output parameters can be used. Refer to your drive instruction manual for
complete descriptions of these output parameters.
•
Parameter 586 (
FLD
CURRENT
REGULATOR
)
•
Parameter 588 (
FIELD
DELTA
)
•
Parameter 589 (
FIELD
FEEDBACK
)
•
Parameter 590 (
FIELD
REFERENCE
)
If you are installing and setting up the Field Current Regulator kit as part of your initial
drive setup, and are using the quick start procedure described in the drive’s instruction
manual, you will be prompted for parameter 510 (
MOTOR
HOT
FLD
AMPS
). In this case,
after you finish with the quick start procedure, make sure that you set parameter 511
(
FIELD
ECONOMY
REF
).