Introduction
Use this document to upgrade the fan inverters on PowerFlex 700S or 700H
frame 10 or frame 11 drives.
What this Kit Contains
Verify that your kit contains the items listed in the following table. If your
kit does not contain the correct items, contact your Allen-Bradley sales
representative.
!
ATTENTION: To avoid an electric shock hazard, ensure that all
power to the drive has been removed before performing the
following.
!
ATTENTION: To avoid an electric shock hazard, verify that the
voltage on the bus capacitors has discharged before performing
any work on the drive. Measure the DC bus voltage at the DC+ &
DC- terminals. The voltage must be zero.
!
ATTENTION: HOT surfaces can cause severe burns. Do not
touch the heatsink surface during operation of the drive. After
disconnecting power allow time for cooling.
!
ATTENTION: Hazard of permanent eye damage exists when
using optical transmission equipment. This product emits intense
light and invisible radiation. Do not look into fiber-optic ports or
fiber-optic cable connectors.
!
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.
Part No.
Quantity:
Description
Frame 10
Kit
Frame 11
Kit
FR10844
1
0
Left-hand Inverter Chassis
FR10845
1
3
Right-hand Inverter Chassis
133256
1
1
Disposable Static Discharge Wrist-strap
Document Outline
- Front Page
- Introduction
- What this Kit Contains
- What You Need to Do
- Step 1: Removing Power from the Drive
- Step 2: Removing Covers from the Power Structure
- Step 3: Preparing Power Structure for Inverter Assembly Removal
- Step 4: Removing Inverter Assemblies
- Step 5: Removing the Inverter from the Old Inverter Assembly
- Step 6: Installing the Inverter on the New Inverter Assembly
- Step 7: Installing the New Inverter Assemblies and Preparing the Drive for Use
- Contacting Rockwell Automation Support
- Pub No. - Date