beautypg.com

Servicing – Rockwell Automation THR Hot Repair Adaptor User Manual

Page 4

background image

4

THR October 2005 – Issue 6

Triguard SC300E

SERVICING

SCOPE

No servicing is necessary, repair is by replacement of the faulty adaptor.

ASSEMBLY AND FITTING

The Hot Repair Adaptor kit comprises two adaptor cards and hardware fittings.

Table 3-1. Contents of Hot Repair Adaptor kit

Item No

(refer to Figure 3-1)

Part No.

Description

No. off

1

099-1245

Hot repair adaptor card

2

2

600-1079

M3 x 3mm spacer

4

3

525-7625

M2.5 x 25mm screw

4

4

507-0175

M2.5 x spring washer

8

5

525-7619

M2.5 x 19mm screw

4

6

442-1016

Cover

2

7

442-1015

Shell

2

CAUTION

Incorrect fitting of an adaptor may result in irreparable damage to the chassis backplane

Prior to the connection of any system cables, fit the Hot Repair Adaptors in the following
manner.

Refer to Figure 3-1.

1.

Check the contents of the Hot Repair Adaptor kit against the list in Table 3-1.

2.

Identify the two adjacent slots to be configured for hot repair.

3.

Remove the four black shrouds from the slot field outlets. Retain two of the shrouds.

4.

Check that none of the backplane connector pins are bent or misaligned.

5.

Carefully position one of the adaptor cards the right way up over two of the backplane

connectors by aligning the top screw holes and gently entering the two top pins into
each connector.