beautypg.com

Rockwell Automation DC2-71, 78, 91, and 98 Drive Fuse Kit Options For all DC2 Controllers except User Manual

Description, Installation

background image

VKSr and Reliancer are trademarks of Reliance Electric Company or its subsidiaries.

ECopyright, Reliance Electric Company, 1992.

INSTRUCTION SHEET D2Ć3250

DC2 VKS DRIVE FUSE KIT OPTIONS

(For all DC2 Controller models except DC2Ć71, 78, 91 and 98)

The products described in this Instruction Manual are manufactured by Reliancer Electric Industrial ComĆ

pany.

DANGER

ONLY QUALIFIED ELECTRICAL PERSONĆ

NEL FAMILIARWITH THE CONSTRUCTION

AND OPERATION OF THIS EQUIPMENT

AND THE HAZARDS INVOLVED SHOULD

INSTALL, OPERATE, AND/OR SERVICE THIS

EQUIPMENT. READ AND UNDERSTAND

THIS MANUAL IN ITS ENTIRETY BEFORE

PROCEEDING. FAILURE TO OBSERVE THIS

PRECAUTION COULD RESULT IN SEVERE

BODILY INJURY OR LOSS OF LIFE.

DANGER

THE USERIS R

ESPONSIBLE FORCONĆ

FORMING TO THE NATIONAL ELECTRICAL

CODE AND ALL OTHERAPPLICABLE LOĆ

CAL

CODES.

WIRING

PRACTICES,

GROUNDING, DISCONNECTS, AND OVERĆ

CURRENT PROTECTION ARE OF PARTICUĆ

LAR IMPORTANCE. FAILURE TO OBSERVE

THIS PRECAUTION COULD RESULT IN SEĆ

VERE BODILY INJURY OR LOSS OF LIFE.

DESCRIPTION

Each kit is supplied as an assembly with fuse

(part # 64676Ć61AR), fuse holder, jumper wire and

mounting hardware. The appropriate fuse kit

should be selected on the basis of the controller

model number per Table 1.

Table 1. Fuse Kit Selection.

Controller

Model Number

Model

Number

Fuse

Current

Rating

(Amps)

All models (except DC2Ć40

Series and DC2Ć71, 78, 91

and 98).

F2DC2000

25

DC2Ć40 Series

F1DC2000

25

DC2Ć71 and DC2Ć78

F1DC2012

(Factory

Installed Only)

25

DC2Ć91 and DC2Ć98

F1DC2412

(Factory

Installed Only)

25

INSTALLATION

F1DC2000 Fuse Kit

DANGER

DO NOT INSTALL MODIFICATION KITS

WITH POWERAPPLIED TO THE UNIT. DISĆ

CONNECT AND LOCK OUT INCOMING

POWERBEFORE ATTEMPTING SUCH INĆ

STALLATION. FAILURE TO OBSERVE THIS

PRECAUTION COULD RESULT IN SEVERE

BODILY INJURY OR LOSS OF LIFE.

DC2Ć40 Series:

ă1. Disconnect and lockout all incoming power to

the DC2 Controller.

ă2. Use a Phillips head screwdriver to remove the

four (4) screws from the faceplate of the ConĆ

troller.

ă3. Place the faceplate to the side of the Controller.

ă4. Use a Phillips screwdriver to remove the two

(2) screws from the blank panel located at the

top of the Controller.

ă5. Place the fuse kit assembly in place of the

blank panel removed in step 4 and then install

the fuse kit assembly using the two (2) screws

removed in the previous step.

ă6. Remove the jumper wire between L1 and 51.

ă7. Using a flathead screwdriver, connect the wire

labeled 51" to terminal 51 of the Controller.

ă8. Using a flathead screwdriver, connect the wire

labeled L1" to terminal L1 of the Controller.

ă9. Install the fuse into the holder.

10. Place the faceplate on the controller and then

install the four (4) screws removed in step 2 of

this procedure.

Trademarks not belonging to Rockwell Automation are property of their
respective companies.

Table of contents