INSTRUCTION SHEET D2Ć3250
DC2 VKS DRIVE FUSE KIT OPTIONS
(For all DC2 Controller models except DC2Ć71, 78, 91 and 98)
The products described in this Instruction Manual are manufactured by Reliancer Electric Industrial ComĆ
pany.
DANGER
ONLY QUALIFIED ELECTRICAL PERSONĆ
NEL FAMILIARWITH THE CONSTRUCTION
AND OPERATION OF THIS EQUIPMENT
AND THE HAZARDS INVOLVED SHOULD
INSTALL, OPERATE, AND/OR SERVICE THIS
EQUIPMENT. READ AND UNDERSTAND
THIS MANUAL IN ITS ENTIRETY BEFORE
PROCEEDING. FAILURE TO OBSERVE THIS
PRECAUTION COULD RESULT IN SEVERE
BODILY INJURY OR LOSS OF LIFE.
DANGER
THE USERIS R
ESPONSIBLE FORCONĆ
FORMING TO THE NATIONAL ELECTRICAL
CODE AND ALL OTHERAPPLICABLE LOĆ
CAL
CODES.
WIRING
PRACTICES,
GROUNDING, DISCONNECTS, AND OVERĆ
CURRENT PROTECTION ARE OF PARTICUĆ
LAR IMPORTANCE. FAILURE TO OBSERVE
THIS PRECAUTION COULD RESULT IN SEĆ
VERE BODILY INJURY OR LOSS OF LIFE.
DESCRIPTION
Each kit is supplied as an assembly with fuse
(part # 64676Ć61AR), fuse holder, jumper wire and
mounting hardware. The appropriate fuse kit
should be selected on the basis of the controller
model number per Table 1.
Table 1. Fuse Kit Selection.
Controller
Model Number
Model
Number
Fuse
Current
Rating
(Amps)
All models (except DC2Ć40
Series and DC2Ć71, 78, 91
and 98).
F2DC2000
25
DC2Ć40 Series
F1DC2000
25
DC2Ć71 and DC2Ć78
F1DC2012
(Factory
Installed Only)
25
DC2Ć91 and DC2Ć98
F1DC2412
(Factory
Installed Only)
25
INSTALLATION
F1DC2000 Fuse Kit
DANGER
DO NOT INSTALL MODIFICATION KITS
WITH POWERAPPLIED TO THE UNIT. DISĆ
CONNECT AND LOCK OUT INCOMING
POWERBEFORE ATTEMPTING SUCH INĆ
STALLATION. FAILURE TO OBSERVE THIS
PRECAUTION COULD RESULT IN SEVERE
BODILY INJURY OR LOSS OF LIFE.
DC2Ć40 Series:
ă1. Disconnect and lockout all incoming power to
the DC2 Controller.
ă2. Use a Phillips head screwdriver to remove the
four (4) screws from the faceplate of the ConĆ
troller.
ă3. Place the faceplate to the side of the Controller.
ă4. Use a Phillips screwdriver to remove the two
(2) screws from the blank panel located at the
top of the Controller.
ă5. Place the fuse kit assembly in place of the
blank panel removed in step 4 and then install
the fuse kit assembly using the two (2) screws
removed in the previous step.
ă6. Remove the jumper wire between L1 and 51.
ă7. Using a flathead screwdriver, connect the wire
labeled 51" to terminal 51 of the Controller.
ă8. Using a flathead screwdriver, connect the wire
labeled L1" to terminal L1 of the Controller.
ă9. Install the fuse into the holder.
10. Place the faceplate on the controller and then
install the four (4) screws removed in step 2 of
this procedure.
Trademarks not belonging to Rockwell Automation are property of their