Rockwell Automation SD3100 Kit Instructions Armature Assembly Heatsink User Manual
Sd3100 armature heatsink assembly replacement
Publication S-3065 - July 1998
R
EPLACEMENT
K
IT
I
NSTRUCTIONS
SD3100 Armature Heatsink Assembly
Replacement
(for 1250 and 1650A Drives)
Contents
This document shows how to remove and replace a heatsink assembly
in a 1250 or 1650A SD3100 drive.
What This Kit Contains
Using the table below, verify that you have received the appropriate
items in your kit:
Other Items Needed
Before you begin, be sure you also have the following:
•
Tools you will need to:
•
Loosen, remove, tighten, and torque bolts (ratchet with
extension and a 9/16” socket, torque wrench for 25 lb-ft)
•
Test for voltages (multimeter)
•
Lift a heatsink assembly
•
Documentation:
•
Your drive system schematics
•
Publication 1395-5.40, Bulletin 1395 Digital DC Drive–
User Manual
•
Publication 2361-5.01, Bulletin 1395 Digital DC Drive in
Bulletin 2361 Motor Control Center for Drive Systems–
User Manual
For this part:
You should receive this quantity:
heatsink assembly
1
Document Outline
- SD3100 Armature Heatsink Assembly Replacement (for 1250 and 1650A Drives)
- Contents
- What This Kit Contains
- Other Items Needed
- Safety Precautions
- Special Instructions
- Preliminary Steps
- Notes on the Heatsink Assembly
- Removing the Assembly
- 1. Using a voltmeter, test the voltage across the three phases, then across the heatsink assembly...
- 2. Unplug the thermoswitch connector (upper assemblies only).
- 3. Unplug the gate lead connector from J1 on each armature-pulse transformer board.
- 4. Remove the two fuses from the front of the assembly.
- 5. Remove the mounting bolts from the top and bottom of the assembly.
- 6. Lift the heatsink assembly out of the drive (a lifting device may be needed).
- Replacing the Heatsink Assembly
- 1. Place the new assembly into the drive (with the snubbers to the right), and rest the lower bra...
- 2. Mount the assembly, securing the three mounting bolts to the top and bottom of the assembly. T...
- 3. Mount the two fuses with the label text upright, and the black indicators away from each other...
- 4. Connect the gate lead connector to J1 on each armature-pulse transformer board. Ensure that th...
- 5. Connect the thermoswitch plug to the incoming thermoswitch lead (upper assemblies only). Ensur...
- Concluding Steps